17
Model C300
Important: To the Operator
Syrup Out Indicator
AUTO
MODE
AUTO
OUT
SYRUP
OK
CO2--OK
WATER--OK
If the word “OUT” appears in one of the columns
next to the word “SYRUP”, it indicates a lack of
syrup or syrup pressure being supplied for the
indicated freezing cylinder. If the unit is in the AUTO
or PRIME modes, the product light will illuminate
and a warning tone will sound for that freezing
cylinder. At this time, replace the appropriate
bag--in--the--box. As a safety feature, the
refrigeration system automatically stops to prevent a
freeze--up in the freezing cylinder.
If a syrup out condition occurs on one side, that side
will enter the HOLD mode at which time refrigeration
remains off, the beater continues to run, and the
CO
2
solenoid is closed for that side to prevent the
dispensing of product. The opposite side will not be
affected.
CO
2
Out Indicator
AUTO
MODE
AUTO
OK
SYRUP
OK
CO2--OUT
WATER--OK
On the LCD, if the word “OUT” appears next to the
word “CO
2
” it indicates a lack of CO
2
being supplied
to the freezer. The product light will also illuminate
and a warning tone will sound. This will continue
until the CO
2
is replaced. If the CO
2
is not replaced
within one minute, the machine will shut down and a
fault message will appear.
Water Out Indicator
AUTO
MODE
AUTO
OK
SYRUP
OK
CO2--OK
WATER--OUT
On the LCD, if the word “OUT” appears next to the
word “WATER”, it indicates a lack of water being
supplied to the freezer. In addition, the product light
will illuminate and a warning tone will sound. This
will continue until the proper amount of water is
supplied to the freezer. If the water is not supplied
within one minute, the machine will shut down and a
fault message will appear.
Audio Alarm Silencer
The audio alarm will be disabled if the ALARM
SILENCE key is pressed. If a new fault or fault
condition occurs or the system mode changes, the
audio alarm will be re--enabled automatically. If the
audio alarm is silenced for greater than 30 minutes
without correcting the fault, it will be re--enabled
automatically.
Product Light
When the light is continuously lit (not flashing) it
indicates that there is an “OUT” condition for syrup,
water, or CO
2
.
When the light is flashing, it indicates that the
product is not at serving viscosity. This will occur
during the initial freeze down, a defrost cycle and a
FAULT condition and during power saver modes.
Sampling Valve
The sampling valve is located behind the lower front
panel. The sampling valve is used to obtain a brix
reading.
Daily Procedures
The following procedure should be performed
daily
.
Remove the splash shield and front drip tray. Take
these parts to the sink and brush--clean them.
Re--install the parts onto the freezer. Use a clean,
sanitized towel and wipe down the front of the
machine, including the doors and spouts.