29
Model C300
Operating Procedures
080507
Cleaning
Step 1
Prepare an approved 100 PPM cleaning solution
(examples: 2--1/2 gal. [9.5 liters] of Kay--5
R
or 2
gal. [7.6 liters] of Stera--Sheen
R
) in a clean, empty
pail. USE WARM WATER AND FOLLOW THE
MANUFACTURER’S SPECIFICATIONS.
Important: Make sure the cleaner is completely
dissolved.
Step 2
Place the syrup line with the old syrup connector into
the pail of cleaner.
Step 3
To place the left freezing cylinder in the SANITIZE
mode, press the MENU (SEL) key. Move the cursor
by pressing the AUTO (-- -->) key until the third line
indicates RINSE / SANITIZE. Press the MENU
(SEL) key. Move the cursor under the word
“SANITIZE”.
RINSE / SANITIZE
RINSE
SANITIZE
EXIT
-- -- -- -- --
<-- -- -- -->
SEL
Pressing the MENU (SEL) key will give you the
option to sanitize the left cylinder. Move the cursor
under the word “YES”. Pressing the MENU (SEL)
key at this time will start the flow of cleaner/sanitizer
through the syrup system into the freezing cylinder.
SANITIZE
LEFT
SIDE
YES
NO
-- -- --
<-- -- -- -->
SEL
Repeat this procedure for the right side freezing
cylinder.
Step 4
Open the prime plugs. Allow each cylinder to fill
approximately 2/3 full. Close each prime plug.
Step 5
Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of each relief
valve, and begins draining into the front drip tray.
The relief valves are located at the top of each mix
tank. Press the OFF (<-- --) key.
Step 6
Press the BEATER (-- -- --) key to agitate the solution
in each freezing cylinder for five minutes.
Figure 44
Step 7
With a pail beneath the door spouts, open the draw
valves and drain all the solution from the the
freezing cylinders. Press the OFF (<-- --) key and
close the draw valves.
Disassembly
Step 1
Be sure the control switch is in the OFF position.
Open the draw valves to make sure all pressure has
been relieved.
Step 2
Open the prime plug. Leave the prime plug open
when removing the freezer door to insure that all
pressure is relieved from the freezing cylinder.
Step 3
Remove the following parts from the freezer and
take them to the sink for brush cleaning.
S
handscrews
S
freezer doors
S
beater assemblies and scraper blades
S
drive shafts
S
front drip tray
S
splash shield