6-6
OPERATING PROCEDURES
Model C303 & C314
Operating Procedures
6
2.
Prepare an approved 100 PPM sanitizing solu-
tion (examples: 2-1/2 gal. [9.5 liters] of
Kay-5
®
or
2 gal. [7.6 liters] of
Stera-Sheen
®
. Use warm water
and follow the manufacturer's specifications.
Important!
Make sure the sanitizer is completely
dissolved.
3.
Using an empty bag of syrup, cut the syrup line
connector from the end of the bag.
Figure 6-22
4.
Connect the syrup line to the syrup line connector
that was cut from the syrup bag.
Figure 6-23
5. With the bag connector attached to the syrup line,
place the syrup line into the pail of sanitizing solution.
Figure 6-24
6. To place a freezing cylinder in the Sanitize mode,
press the MENU SELECT key. Move the cursor by
pressing the AUTO (- ->) key until the third line
indicates RINSE / SANITIZE.
7. Press the MENU SELECT key. Move the cursor
under the word SANITIZE by pressing the OFF (<- -)
key.
8. Pressing the MENU SELECT key will give you the
option for sanitizing a freezing cylinder. Move the cur-
sor under the desired barrel.
17011
17041
17013
OPERATOR MENU
A B C D E F G H I
RINSE / SANITIZE
L
E
S
>
-
-
-
-
<
RINSE / SANITIZE
RINSE
SANITIZE
EXIT
- - - - -
L
E
S
>
-
-
-
-
<
SEL
<- - - ->
EXIT
SANITIZE
BARREL
1 2 3
Summary of Contents for C303
Page 14: ...3 4 SAFETY Model C303 C314 Safety 3 Notes...
Page 41: ...OPERATING PROCEDURES 6 13 Model C303 C314 Operating Procedures 6...
Page 43: ...7 2 OPERATOR CHECKLIST Model C303 C314 Operator Checklist 7 Notes...
Page 47: ...9 2 PARTS REPLACEMENT SCHEDULE Model C303 C314 Parts Replacement Schedule 9 Notes...
Page 53: ...11 4 LIMITED WARRANTY ON PARTS Model C303 C314 Limited Warranty on Parts 11 Notes...