OPERATING PROCEDURES
6-7
Model C707
Operating Procedures
6
Figure 6-23
8. Once the sanitizer stops flowing from the door spout,
raise the draw handle. Press the WASH key to cancel
the beater motor operation.
Figure 6-24
Note:
Be sure your hands are clean and sanitized
before continuing these instructions.
9. Lubricate the mix feed tube O-rings on the end of the
tube with the small hole on the side. Stand the mix
feed tube in the corner of the mix hopper.
Figure 6-25
Priming
1. Place an empty pail beneath the door spout and
lower the draw handle. Be sure the prime plug is still
in the up position. Pour 2 gal. (7.6 L) of
fresh
mix into
the hopper and allow it to flow into the freezing
cylinder. This will force out any remaining sanitizing
solution. When full strength mix is flowing from the
door spout, raise the draw handle.
Note:
Use only fresh mix when priming the freezer.
2. Once a
steady
stream of mix starts to flow from the
prime plug opening in the bottom of the freezer door,
push down the prime plug.
Figure 6-26
101558