5-14
USER INTERFACE
Models C709 & C717
User Interface
5
Lockout History
The LOCKOUT HISTORY screen displays a history of
the last 100 soft locks, hard locks, brush-clean dates, and
aborted Heat cycles. Page numbers are indicated in the
upper right-hand corner. Page 1 always contains the
most recent failure.
The second line of the screen displays the date and time
a failure occurs. The third line indicates the reason for a
failure and when a successful brush-cleaning has
occurred. Some failures occur with multiple reasons.
When this occurs, a page will be generated for each
reason.
Use the arrow keys to move forward or backward to view
each screen. Listed below are the variable messages
that may appear:
Faults - Entering Heat Treatment Cycle
POWER SWITCH OFF—
The power switch is OFF.
AUTO OR STBY OFF—
The control was not in the Auto
or Standby mode.
MIX OUT FAILURE—
A Mix Out condition was present.
NO HEAT CYCLE TRIED—
The Auto Heat Time was set
to attempt a Heat cycle more than 24 hours after the last
successful Heat cycle.
Faults in Heat Mode
HEAT MODE FAILURE—
The maximum allowable heat
mode time exceeded 90 minutes.
COOL MODE FAILURE—
The maximum allowable cool
mode time exceeded 90 minutes for UVC3 machines or
120 minutes for UVC4 machines.
TOTAL TIME FAILURE—
The maximum allowable total
Heat Treatment time exceeded 4 hours.
BRUSH CLEAN TIMEOUT—
The total days in operation
exceeded the brush-clean cycle setting.
POWER SWITCH OFF—
The power switch was turned
off during the Heat cycle.
POWER FAIL IN H/C—
A power failure occurred during
the Heat Treatment cycle.
MIX LOW FAILURE—
The mix level in the hopper is too
low for a successful Heat cycle.
BEATER OVLD H/C—
The overload tripped for the
beater motor.
BRL THERM FAIL—
The thermistor sensor for the
freezing cylinder failed.
HOPPER THERM FAIL—
The thermistor sensor for the
hopper failed.
HPCO H/C—
The high-pressure switch opened during
the Heat Treatment cycle.
Faults in Auto Mode
(L/R) HPR>41F (5C) AFTER 4 HR—
The mix
temperature in the hopper was above 41°F (5°C) for
more than 4 hours.
(L/R) BRL>41F (5C) AFTER 4 HR—
The mix
temperature in the freezing cylinder (barrel) was above
41°F (5°C) for more than 4 hours.
(L/R) HPR>41F (5C) AFTER PF—
The mix temperature
in the hopper was above 41°F (5°C) more than 4 hours
following a power failure.
(L/R) BRL>41F (5C) AFTER PF—
The mix temperature
in the freezing cylinder (barrel) was above 41°F (5°C)
more than 4 hours following a power failure.
(L/R) HPR>45F (7C) AFTER 1 HR—
The mix
temperature in the left or right hopper was above 45°F
(7°C) for more than 1 hour.
(L/R) BRL>45F (7C) AFTER 1 HR—
The mix
temperature in the left or right freezing cylinder (barrel)
was above 45°F (7°C) for more than 1 hour.
(L/R) HPR>59F (15C)—
The mix temperature in the
hopper exceeded 59°F (15°C).
(L/R) BRL>59F (15C)—
The mix temperature in the
freezing cylinder (barrel) exceeded 59°F (15°C).
(L/R) TOO COLD—
The mix temperature in the freezing
cylinder (barrel) has dropped below 10°F (-12°C).
LOCKOUT HISTORY
1
00/00/00
00:00
REASON
> Exit
Summary of Contents for C709
Page 8: ...1 4 TO THE INSTALLER Models C709 C717 To the Installer 1 Notes...
Page 22: ...4 10 OPERATOR PARTS IDENTIFICATION Models C709 C717 Operator Parts Identification 4 Notes...
Page 58: ...8 4 TROUBLESHOOTING GUIDE Models C709 C717 Troubleshooting Guide 8 Notes...
Page 60: ...9 2 PARTS REPLACEMENT SCHEDULE Models C709 C717 Parts Replacement Schedule 9 Notes...
Page 64: ...10 4 LIMITED WARRANTY ON EQUIPMENT Models C709 C717 Limited Warranty on Equipment 10 Notes...
Page 68: ...11 4 LIMITED WARRANTY ON PARTS Models C709 C717 Limited Warranty on Parts 11 Notes...