C713 Operator Training
C713 Operator Training
8
C713 Operator Training
C713 Operator Training
Hard locks require that the machine be brush cleaned before it can return to the AUTO mode of
operation.
Typical Reasons:
HPR>41F (5C) AFTER 4 HR - The mix temperature in the hopper was above 41°F (5°C) more than
four hours.
BRL>41F (5C) AFTER 4 HR - The mix temperature in the freezing cylinder was above 41°F (5°C)
more than four hours.
HPR>41F (5C) AFTER PF - The mix temperature in the hopper was above 41°F (5°C) more than
four hours following a power failure.
BRL>41F (5C) AFTER PF - The mix temperature in the freezing cylinder was above 41°F (5°C)
more than four hours following a power failure.
HPR>45F (7C) AFTER 1 HR - The mix temperature in the hopper was above 45°F (7°C) more than
one hour.
BRL>45F (7C) AFTER 1 HR - The mix temperature in the freezing cylinder was above 45°F (7°C)
more than one hour.
HPR>59F (15C) - The mix temperature in the hopper exceeded 59°F (15°C).
BRL>59F (15C) - The mix temperature in the freezing cylinder exceeded 59°F (15°C).
Solution:
Turn off machine, disassemble and clean.
FREEZER LOCKED
Hard locks are designed to
insure product safety. The
machine will go into this mode
when the product mix quality
becomes compromised.
Hard Locks