background image

C713 Operator Training

C713 Operator Training

C713 Operator Training

C713 Operator Training

15

If the mix gets too cold, the reset button will “trip” to protect the beater motor. This could be caused 

by insufficient mix in the freezing cylinder. If this occurs, inspect the feed tube to verify that it is 

properly assembled.

Freezing Cylinder: Reset

Summary of Contents for c713

Page 1: ......

Page 2: ......

Page 3: ...C713 Operator Training 1 Introduction...

Page 4: ...tical The rate must be 5 7 5 oz 150 225 g per 10 seconds The way we measure capacity is by how many servings can be drawn before the machine needs time to recover the mix to the proper viscosity The C...

Page 5: ...s are necessary The machine will cease refrigeration for 10 minutes to maintain servable product during the day Product that is overbeaten is broken down Broken down product is caused by longer than n...

Page 6: ...ervice technician Cause Freeze up in mix inlet hole Remedy Call an authorized service technician Cause Mix feed tube is installed incorrectly or the air orifice is not installed Remedy Brush clean the...

Page 7: ...on the front of the machine are off to assure successful operation and product dispensing Milkstone build up can cause an erroneous mix low indication Open the hopper lid and fill the hopper with new...

Page 8: ...ers the STANDBY mode of operation Open the hopper lid and fill the hopper with new mix The mix out indicator light will turn off after the mix covers the bottom sensor The mix low indicator light will...

Page 9: ...or Training 7 After hour 99 the brush clean counter will change to a letter and a number example A0 A1 B0 B1 etc Brush Clean Counter The Brush Clean Counter will display the number of hours since the...

Page 10: ...ailure BRL 41F 5C AFTER PF The mix temperature in the freezing cylinder was above 41 F 5 C more than four hours following a power failure HPR 45F 7C AFTER 1 HR The mix temperature in the hopper was ab...

Page 11: ...C713 Operator Training C713 Operator Training 9 INTERACTIVE MODULE Move your mouse across the panel to learn what each part does Accessing Data...

Page 12: ...C713 Operator Training 10 C713 Operator Training Menu Simulator Click the switch to turn the power ON...

Page 13: ...the speed of product dispensing For optimum product quality the rate of dispensing should be 5 to 7 5 oz 142 213 g in a 10 sec draw If the dispensing rate is set higher or lower the risk is poor prod...

Page 14: ...stalling the beater assembly check the scraper blades If they are in good condition take one of the scraper blades and slip it under the hook at the front of the beater Wrap the blade around the beate...

Page 15: ...in a criss cross pattern to insure the door is snug Step 14 Slide the three o rings into the grooves of each standard draw valve Slide the H ring and o ring into the grooves of the center draw valve L...

Page 16: ...the small o ring into the groove of the air orifice Do not lubricate the o ring Note Make sure the hole in the air orifice is clean and is not clogged If the hole in the air orifice should become clo...

Page 17: ...If the mix gets too cold the reset button will trip to protect the beater motor This could be caused by insufficient mix in the freezing cylinder If this occurs inspect the feed tube to verify that i...

Page 18: ...osits 4 Dispose of o rings and seals if they are worn torn or fit too loosely and replace with new ones 5 Follow all lubricating procedures as outlined in Assembly 6 Check the condenser and filters fo...

Page 19: ...the ON position Step 6 Touch the WASH symbol This will cause the sanitizing solution in the freezing cylinder to be agitated Step 7 With an empty pail beneath the door spouts raise the prime plug Step...

Page 20: ...remove all sanitizing solution When only fresh mix is flowing close the draw valve Step 2 Once a steady stream of mix starts to flow from the prime plug opening in the bottom of the freezer door push...

Page 21: ...un container beneath the door spout Press the WASH key and open the draw valve Drain the remaining product from the freezing cylinder and mix hopper When the flow of product stops press the WASH key a...

Page 22: ...e the machine is in the WASH mode Step 2 With a mix pail beneath the door spout raise the prime plug and touch the WASH symbol Step 3 When a steady stream of rinse water is flowing from the prime plug...

Page 23: ...probes Using the double ended brush clean the mix inlet hole Note Do not brush clean the mix inlet hole while the machine is in the WASH mode Step 4 Touch the WASH symbol This will cause the cleaning...

Page 24: ...drive shaft seal from the drive shaft Step 5 Remove the freezer door gasket front bearing pivot pin draw handle draw valve prime plugs and design caps Remove the three o rings from the draw valve Rep...

Page 25: ...isassembled parts in the cleaning solution making sure all lubricant and mix film is removed Be sure to brush all surfaces and holes especially the holes in the freezer door Step 3 Rinse all parts wit...

Page 26: ...thorized service technician The mix in the hopper is too warm Cause Hopper cover is not in position Remedy Clean and sanitize hopper cover and place in position Cause The hopper temperature is out of...

Page 27: ...Training 25 Troubleshooting LCD No control panel functions with power switch ON Cause Machine is unplugged Remedy Plug into wall receptacle Cause Circuit breaker is OFF or blown fuse Remedy Turn the c...

Page 28: ...er door Cause Beater assembly is bent Remedy Replace beater assembly Cause Gear box is out of alignment Remedy Call an authorized service technician The drive shaft is stuck in the drive coupling Caus...

Page 29: ...e machine in AUTO Cause Machine not in AUTO mode Remedy Select AUTO and allow machine to cycle off before drawing product Cause The feed tube is not properly installed Remedy Make sure the feed tube i...

Page 30: ...ated or worn Remedy Lubricate properly or replace the seal Cause The drive shaft seal is installed inside out Remedy Install correctly Cause Inadequate lubrication of the drive shaft Remedy Lubricate...

Page 31: ...edy Call an authorized service technician Cause Freeze up in mix inlet hole Remedy Call an authorized service technician Cause Mix feed tube is installed incorrectly or the air orifice is not installe...

Page 32: ...he Taylor Operator Manual or local Taylor Distributor for part numbers Note For air cooled units condensers should be cleaned monthly with a soft brush Design Cap Every 3 months replace the following...

Page 33: ...aining C713 Operator Training 31 Six Months Parts Replacement Every 6 months inspect replace if necessary the following Black Bristle Brush 1 x 2 Double Ended Brush White Bristle Brush 1 x 2 White Bri...

Page 34: ...C713 Operator Training 32 C713 Operator Training Quiz Shakes Start Exit Game C713 the Game...

Page 35: ...C713 Operator Training C713 Operator Training 33 EXIT GAME...

Page 36: ...ng 34 C713 Operator Training Sc o r e EXIT GAME 1What will worn scraper blades cause Long running refrigeration times The freezer to be unable to keep up with customer needs The mix to become broken d...

Page 37: ...perator Training 35 Sc o r e EXIT GAME 2What will happen if the air orifice is not installed on the mix tube Product will have incorrect air to mix ratio No product will dispense The product will free...

Page 38: ...Operator Training Sc o r e EXIT GAME 3What is the cause when a rear drip pan fills with an excessive amount of mix Worn rear shell bearing Worn damaged or incorrect drive shaft seal Incorrect lubricat...

Page 39: ...C713 Operator Training C713 Operator Training 37 Sc o r e EXIT GAME 4How often should scraper blades be replaced Every 4 months Never Every 3 months or as needed None of the above...

Page 40: ...C713 Operator Training 38 C713 Operator Training Sc o r e EXIT GAME 5If the mix out light on the control is lit what mode will the freezer be in Auto Heat Wash Standby...

Page 41: ...erator Training C713 Operator Training 39 Sc o r e EXIT GAME 6What is the serving temperature of soft serve ice cream 16 to 18 F 8 8 to 7 7 C 14 to 20 F 10 to 6 6 C 20 to 24 F 6 6 to 4 4 C None of the...

Page 42: ...or Training 40 C713 Operator Training Sc o r e EXIT GAME 7What is the draw rate set for 5 7 oz 142 213 g in 10 seconds 8 15 oz 227 425 g in 10 seconds 7 10 oz 198 283 g in 10 seconds 5 7 oz 142 213 g...

Page 43: ...3 Operator Training C713 Operator Training 41 Sc o r e EXIT GAME 8What is the term broken down product used to describe Un servable product Wet appearing soft product Over beaten product All of the ab...

Page 44: ...C713 Operator Training 42 C713 Operator Training Sc o r e EXIT GAME 9How often should tune up kits be installed Monthly Yearly Every 3 months None of the above...

Page 45: ...C713 Operator Training C713 Operator Training 43 Sc o r e EXIT GAME 10 What is the access code for entering the operator s menu 7348 1234 8309 None of the above...

Page 46: ...C713 Operator Training 44 Sc o r e Congratulations You now have a great understanding of your Taylor C713 Freezer With this knowledge you ll be able to keep it running at its optimum level EXIT GAME...

Reviews: