Priming
Note: Use only FRESH MIX when priming the freezer.
Step 1
Place an empty mix pail beneath the door spouts. With the prime plug in the UP position, pour 2-1/2
gallons (9.5 liters) of FRESH mix into the mix hopper and allow it to flow into the freezing cylinder.
Open the draw valve to remove all sanitizing solution. When only fresh mix is flowing, close the draw
valve.
Step 2
Once a steady stream of mix starts to flow from the prime plug opening in the bottom of the freezer
door, push the prime plug down.
Step 3
Install the end of the feed tube with the hole in it into the mix inlet hole in the mix hopper. Make sure
the air orifice is installed in the feed tube.
Step 4
Select the AUTO symbol.
Fill the hopper with fresh mix and place the mix hopper cover in position.
Repeat these steps for the other side of the machine.