1-2
TO THE INSTALLER
Model C723
To the Installer
1
CAUTION!
This machine must be installed on
a level surface to avoid the hazard of tipping. Extreme
care should be taken in moving this machine for any
reason. Two or more persons are required to safely move
this machine. Failure to comply may result in personal
injury or damage to the machine.
The authorized installer should inspect the machine and
promptly report any damage to the local authorized
Taylor distributor.
This machine is made using USA sizes of hardware. All
metric conversions are approximate and vary in size.
Water Connections
(Water-Cooled Machines Only)
An adequate cold water supply must be provided with a
hand shutoff valve. On the back, right side of the
machine, two 3/8 in. (9.5 mm) I.P.S. water connections
for inlet and outlet are provided for easy hookup.
Permanently connect the machine using 1/2 in. (12.7
mm) inside diameter water lines. (Flexible lines are
recommended, if local codes permit.) Depending on local
water conditions, it may be advisable to install a water
strainer to prevent foreign substances from clogging the
automatic water valve. There will be only 1 water-in and 1
water-out connection.
Do not
install a hand shutoff valve
on the water-out line! Water should always flow in this
order: first, through the automatic water valve; second,
through the condenser; and third, through the outlet
fitting to an
open trap drain.
IMPORTANT!
A backflow prevention device is
required on the incoming water connection side. Please
see the applicable national, state, and local codes for
determining the proper configuration. Water pressure to
the unit must not exceed 150 psi (1034 kPa).
Electrical Connections
IMPORTANT!
In the United States, this
machine is intended to be installed in accordance with
the National Electrical Code (NEC), ANSI/NFPA 701987.
The purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
In all other areas of the world, the machine should be
installed in accordance with the existing local codes.
Please contact your local authorities if you have any
questions.
Each machine requires one power supply for each data
label on the machine. Check the data label(s) on the
machine for branch circuit overcurrent protection or fuse,
circuit ampacity, and other electrical specifications.
See the wiring diagram provided inside the electrical box
for proper power connections.
WARNING!
This machine must be properly
grounded. Failure to do so can result in severe personal
injury from electrical shock.
IMPORTANT!
This machine is provided with
an equipotential grounding lug that is to be properly
attached to the rear of the frame by the authorized
installer. The installation location is marked by the
equipotential bonding symbol (5021 of IEC 60417-1) on
the removable panel and the frame.
WARNING!
Avoid injury.
•
DO NOT
operate the machine unless it is
properly grounded.
•
DO NOT
operate the machine with fuses larger
than specified on the machine's data label.
•
All repairs should be performed by an
FOLLOW YOUR LOCAL ELECTRICAL CODES.
Summary of Contents for C723
Page 14: ...3 4 SAFETY Model C723 Safety 3 Notes ...
Page 42: ...6 10 OPERATING PROCEDURES Model C723 Operating Procedures 6 Notes ...
Page 48: ...9 2 PARTS REPLACEMENT SCHEDULE Model C723 Parts Replacement Schedule 9 Notes ...
Page 52: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C723 Limited Warranty on Equipment 10 Notes ...
Page 56: ...11 4 LIMITED WARRANTY ON PARTS Model C723 Limited Warranty on Parts 11 Notes ...