25 - ENGLISH
9.
(*)
These parameters vary for each unit and variant.
(**)
The parameters may vary depending on the software version or customisation. It is
always possible to refer to the test inspection board supplied with the machine.
“MEB²” BOARD PROGRAMMING TABLE (**)
P DESCRIPTION MIN
MAX
CH02 STEP
P1 Model
Selection
1
2 2
1= TWIN
2= CH02
P2
Tank probe correction (TEV)
-10°
+10°
*
0,5°C
P3
Probe correction
fluid (TEF)
-10° +10°
*
0,5°C
P4
Tank overtemperature
compensation when TEV>40°C
-10° +10°
*
0,5°C
P5
TEF Control Lim. in SEMI-
AUTOMATIC
30° 130°
98° 1°C
P6
TEF Control Lim. in AUTOMATIC
85° and 65°
30° 130°
98° 1°C
P7
Not active
P8
Not active
P9
Lim. control hysteresis TEF
1°
10°
1°
1°C
P10 Temperature indication on display
0
1
1
0=°F
1=°C