6
Models 150, 152, 162, 168
Safety
130722
S
DO NOT
allow untrained personnel to operate
this unit.
S
DO NOT
put objects or fingers in door spout.
S
DO NOT
operate the freezer unless all service
panels and access doors are restrained with
screws.
S
DO NOT
remove the freezer door or beater
assembly unless the control switches are in
the “OFF” position.
Failure to follow these instructions may result in severe
personal injury from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
S
DO NOT
put objects or fingers in the door
spout. This may contaminate the product and
cause severe personal injury from blade
contact.
S
USE EXTREME CAUTION
when removing
the beater asssembly. The scraper blades are
very sharp.
This freezer must be placed on a level
surface. Failure to comply may result in personal injury
or equipment damage.
Access to the service area of the unit is
restricted to persons having knowledge and practical
experience with the appliance, in particular as far as
safety and hygiene are concerned.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to the
cleaning section of this manual for the proper
procedure to clean this unit.
This unit is designed to maintain product
temperature under 41
_
F (5
_
C). Any product being
added to this unit must be below 41
_
F (5
_
C). Failure
to follow this instruction may result in health hazards
and poor freezer performance.
DO NOT
obstruct air intake and discharge openings:
S
150 and 152:
Minimum of 6” (152 mm) of
clearance around both sides. Install the skirt
provided on the right side of the unit and place
the back of the unit against a wall to prevent
recirculation of warm air.
S
162:
Minimum of 6” (152 mm) on all sides.
Install the skirt provided on the rear of the unit.
S
168:
Minimum of 3” (76 mm) on all sides.
Install the skirt provided on the rear of the unit.
For Indoor Use Only:
This unit is designed to operate
indoors, under normal ambient temperatures of
70
_
-75
_
F (21
_
-24
_
C). The unit has successfully
performed in high ambient temperatures of
104
_
(40
_
C) at reduced capacities.
DO NOT
run the unit without product. Failure to follow
this instruction can result in damage to the unit.
NOISE LEVEL:
Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the unit and at a height of 1.6
meters from the floor.