43
Models C708 & C716
Operating Procedures
150622
Figure 50
Step 5
Install the pump end of the mix feed
tube and secure with the cotter pin.
Failure to
follow this instruction could result in sanitizer
spraying on the operator. (See Figure 51.)
Figure 51
Step 6
Prepare another pail of approved 100 PPM sanitiz-
ing solution (examples: 2-1/2 gal. [9.5 liters] of
Kay-5
R
or 2 gal. [7.6 liters] of Stera-Sheen
R
).
USE WARM WATER AND FOLLOW THE MANU-
FACTURER'S SPECIFICATIONS.
Step 7
Pour the sanitizing solution into the mix hopper.
Step 8
Brush the exposed sides of the hopper.
Step 9
Place the power switch in the ON position.
Step 10
Touch the WASH key
. This will cause the
sanitizing solution in the freezing cylinder to be
agitated. Wait at least 5 minutes before proceeding
with these instructions.
Step 11
With a pail beneath the door spout(s), open the draw
valve and touch the PUMP key
. Open and close
the draw valve 6 times.
Note:
Momentarily open the center draw valve to
sanitize the center door spout (C716 only).
Step 12
Draw off the remaining sanitizing solution.
Step 13
Touch the WASH and PUMP keys
and close
the draw valve. (See Figure 52.)
Figure 52
IMPORTANT! The unit must NOT be placed in
AUTO until all sanitizing solution has been
removed from the freezing cylinder and proper
priming procedures have been completed.
Failure to follow this instruction may result in
damage to the freezing cylinder.
Note: Be sure your hands are clean and
sanitized before going on in these instructions.