26
Models C708 & C716
Important: To the Operator
050628
The LOCKOUT HISTORY screen displays a history
of the last 40 soft locks, hard locks, brush clean
dates, or aborted heat cycles. Page numbers are
indicated in the upper right hand corner. Page 1
always contains the most recent failure.
LOCKOUT HISTORY
1
00/00/00
00:00
Reason
> Exit
The second line of the screen displays the date and
time a failure occurs. The third line indicates the
reason for a failure, or will indicate if a successful
brush cleaning has occurred. Some failures occur
with multiple reasons. When this occurs, a page will
be generated for each reason.
Use the arrow symbols to advance forward or move
backward to view each screen. Listed below are the
variable messages that may appear.
Faults Occurring Entering a Heat
Treatment Cycle
POWER SWITCH OFF -
The power switch is OFF.
AUTO OR STBY OFF -
The control was not in the
AUTO or STANDBY mode.
MIX OUT FAILURE -
A Mix Out condition was
present.
NO HEAT CYCLE TRIED -
The Auto Heat Time
was set to attempt a heat cycle more than 24 hours
after the last successful heat cycle.
Faults Occurring While in Heat Mode
HEAT MODE FAILURE -
The maximum allowable
heat mode time exceeded 90 minutes.
COOL MODE FAILURE -
The maximum allowable
cool mode time exceeded 90 minutes.
TOTAL TIME FAILURE -
The maximum allowable
total heat treatment time exceeded 4 hours.
BRUSH CLEAN TIMEOUT -
The total days in
operation exceeded the brush clean cycle setting.
POWER SWITCH OFF -
The power switch was
turned OFF during the heat cycle.
POWER FAIL IN H/C -
A power failure occurred
during the heat treatment cycle.
MIX LOW FAILURE -
The mix level in the hopper is
too low for a successful heat cycle.
BEATER OVLD H/C -
The overload tripped for the
beater motor.
BRL THERM FAIL -
The thermistor sensor for the
freezing cylinder failed.
HOPPER THERM FAIL -
The thermistor sensor for
the hopper failed.
HPCO H/C -
The high pressure switch opened
during the heat treatment cycle.
Faults Occurring While in AUTO Mode
(L/R) HPR>41F (5C) AFTER 4 HR -
The mix
temperature in the hopper was above 41°F (5°C)
more than four hours.
(L/R) BRL>41F (5C) AFTER 4 HR -
The mix
temperature in the freezing cylinder was above 41°F
(5°C) more than four hours.
(L/R) HPR>41F (5C) AFTER PF -
The mix
temperature in the hopper was above 41°F (5°C)
more than four hours following a power failure.
(L/R) BRL>41F (5C) AFTER PF -
The mix
temperature in the freezing cylinder was above 41°F
(5°C) more than four hours following a power failure.
(L/R) HPR>45F (7C) AFTER 1 HR -
The mix
temperature in the left or right hopper was above
45
_
F (7
_
C) more than one hour.
(L/R) BRL>45F (7C) AFTER 1 HR -
The mix
temperature in the left or right barrel was above
45
_
F (7
_
C) more than one hour.
(L/R) HPR>59F (15C) -
The mix temperature in the
hopper exceeded 59°F (15°C).
(L/R) BRL>59F (15C) -
The mix temperature in the
hopper exceeded 59°F (15°C).
Summary of Contents for Wawa C708
Page 1: ...Models C708 C716 Heat Treatment Soft Serve Freezer Operating Instructions 059061 M 6 17 08...
Page 71: ...Model C708 057010 27 Rev 2 08...
Page 72: ...Model C708 057010 27 Inset Rev 2 08...
Page 73: ...Model C708 057010 33 Rev 2 08...
Page 74: ...Model C708 057010 40 Rev 2 08...
Page 75: ...Model C708 057010 58 Rev 2 08...
Page 76: ...Model C716 059900 27 Rev 2 08...
Page 77: ...Model C716 059900 27 Inset Rev 2 08...
Page 78: ...Model C716 059900 33 Rev 2 08...
Page 79: ...Model C716 059900 40 Rev 2 08...
Page 80: ...Model C716 059900 58 Rev 2 08...