27
Models C708 & C716
Important: To the Operator
050628
The HEAT CYCLE SUMMARY screen displays the
hours since the last heat cycle, the hours since the
product temperature was above 150
_
F (65.6
_
C),
and the number of heat cycles completed since the
last brush clean date.
HEAT CYCLE SUMMARY
HRS SINCE HC
0
HRS SINCE 150
0
HC SINCE BC
0
The HEAT CYCLE DATA screen contains a record
of up to 366 heat treatment cycles. The most recent
heat cycle data will be shown first.
Each heat cycle record has three screens. The first
screen displays the month and day of the heat cycle,
the start time and end time, and the fault description.
The bottom line displays the record number and
indicates if a power failure occurred during the heat
cycle (POWER FAILURE IN HC).
HEAT TREAT CYCLE
01/01
02:00
05:14
NO FAULT FOUND
1
Touch the UP arrow symbol to advance forward
through the data pages. Touch the DOWN arrow
symbol to reverse the page direction.
Hopper and barrel temperature records for each side
of the freezer are displayed in the second and third
screens. The second screen shows the left side (L)
side of the freezer.
The third screen shows the right side (R) of the
freezer.
The top line of these screens shows the hopper (H)
and barrel (B) temperatures recorded at the end of
the Heat Treat Cycle and indicates the side (L or R)
of the freezer.
The remaining lines indicate the following:
HEAT
= Total time for the hopper (h) and barrel (b)
to reach 150.9°F (66.1°C).
OVER
= Total time the hopper (h) and barrel (b)
temperature was above 150°F (65.6°C).
COOL
= Total time the hopper (h) and barrel (b)
temperature was above 41°F (5°C) during the COOL
phase.
PEAK
= Highest temperature reading for the hopper
(h) and barrel (b) during the Heat Treatment Cycle.
H: 40.9
B:26.3
L
HEAT
OVER
COOL
PEAK
1:12
0:49
h
1:19
161.0
0:46
1:11
b
0:15
169.7
H: 38.0
B:23.7
R
HEAT
OVER
COOL
PEAK
1:09
0:52
h
1:11
161.2
0:66
1:00
b
0:11
169.9
The HEAT time indicates the amount of time taken
in each zone to reach 150.9°F (66.1°C). Each zone
must remain above 150°F (65.6°C) for a minimum of
35 minutes.
Touch the UP arrow symbol to advance to the next
page or the DOWN arrow symbol to view the
previous page. A Heat Cycle Failure message will
display on the first screen if a failure occurred.
Listed below are variable failure code messages
which could appear on line 2.
HT
HEAT TIME FAILURE
Mix temperature did not rise above 151
_
F
(66.1
_
C) in less than 90 minutes.
CL
COOL MODE FAILURE
Mix temperature in the hopper and freezing
cylinder did not fall below 41
_
F (5
_
C) in less
than 90 minutes.
TT
TOTAL TIME FAILURE
The heat treatment cycle must be completed
in no more than 4 hours.
ML
MIX LOW FAILURE
The Heat Phase or Cool Phase time was
exceeded and a mix low condition was pres-
ent.
MO
MIX OUT FAILURE
A mix out condition was detected at the start
or during the heat cycle.
BO
BEATER OLVD IN HC
A beater overload occurred during the heat
cycle.
HO
HPCO IN HEAT CYCLE
A high pressure cut-out condition occurred
during the heat cycle.
Summary of Contents for Wawa C708
Page 1: ...Models C708 C716 Heat Treatment Soft Serve Freezer Operating Instructions 059061 M 6 17 08...
Page 71: ...Model C708 057010 27 Rev 2 08...
Page 72: ...Model C708 057010 27 Inset Rev 2 08...
Page 73: ...Model C708 057010 33 Rev 2 08...
Page 74: ...Model C708 057010 40 Rev 2 08...
Page 75: ...Model C708 057010 58 Rev 2 08...
Page 76: ...Model C716 059900 27 Rev 2 08...
Page 77: ...Model C716 059900 27 Inset Rev 2 08...
Page 78: ...Model C716 059900 33 Rev 2 08...
Page 79: ...Model C716 059900 40 Rev 2 08...
Page 80: ...Model C716 059900 58 Rev 2 08...