35
Models C708 & C716
Operating Procedures
Step 4
Insert the piston into the retaining pin hole end of the
pump cylinder. (See Figure 35.)
15123
Figure 35
Step 5
Assemble the valve cap. Slide the o-ring into the
groove of the valve cap. DO NOT lubricate the
o-ring. (See Figure 36.)
15109
Figure 36
Step 6
Slide the pump valve gasket into the holes on the
cap. DO NOT lubricate the gasket. (See Figure 37.)
15110
Figure 37
Step 7
Insert the valve body cap into the hole in the mix
inlet adapter. (See Figure 38.)
15111
Figure 38
Step 8
Insert the mix inlet assembly into the pump cylinder.
(See Figure 39.)
15112
Figure 39
The adapter must be positioned into the notch
located at the end of the pump cylinder.