CHIPCARD option 

 
An  option  to  increase  independence  and  flexibility,  using  tw o  types  of  ChipCards  to  transfer  data  betw een 
members of  the F-SCAN family, w as designed into the F-SCA N5. 

 

Progra m  data  consisting  of  frequency  values  can  only  be  shared  betw een  F-SCA N4,  F-SCAN3,  F- SCA N 
COMPACT and the MinDevice using the ChipCard. 

 

The use  of the ChipCard  PLUS allows  the transfer of all types  of program data sets to and from F-SCA N4, F-
SCA N3 and F-SCAN MOBILE.  
 

Insert the ChipCard vertically into the reader on right hand side of the device.    
 
 
 
 
 

 
The menu ChipCard opens and offers 4 choices:  
 
-  Touch  the first  line to save all of  the 100 program positions, w hich  hold frequencies  only,  on the ChipCard 

for use in an F-SCA N COMPA CT.  

 
-  Touch  the  second  line  to  overwrite  the  100  program  positions  of  the  F-SCAN5  w ith  the  data from  an  F-

SCA N COMPA CT.  DIRP- or  EA P-data sets previously stored in program positions  in the  F-SCAN5 w ill be  
lost.  

 
-  Touch the third line to store the frequency values of the program position presently open in the F-SCAN5 on 

the ChipCard for use in a MinDevice.  

 
-  Touch  the  fourth  line  to  only  copy  one  protocol  from  the  ChipCard.  A  selection  menu  opens  and  the 

selected  program  is  copied  to  the  first  free  program  position.  If  no  free  program  is  available,  progra m 
number 1 is used. 

 
Removal of the  ChipCard  from the reader  resets  the  F-SCAN5 to the  menu active  w hen the ChipCar d w as 
inserted. 
 
 

Use of the ChipCard PLUS 

 
The follow ing menu opens w hen a ChipCard PLUS is inserted into the reader: 
 
-  Touch  the  first  line  to  store  the content  of  the  memory w ith  the  100  program  positions  on  the  Chip Card 

PLUS. 

 
-  Touch  the  second  line  to  overw rite  the  100  progra m  positions  of  the  F-SCA N5  w ith  the  data  from  the 

ChipCard  PLUS.  

 

-  Touch BACK UP ABC LIST to store the AB C list on the ChipCard  PLUS. 
 

Touch  RESTORE ABC LIST to copy the ABC list f rom ChipCard into the device.  An already installed ABC 

list w ill be overw ritten.

 

Summary of Contents for F-SCAN5

Page 1: ...uency Synthesizer F SCAN5 Firmware Version FS5 V1 0x INSTRUCTION MANUAL This symbol identifies the equipment as type B Attention CONSULT ACCOMPANYING DOCUMENTS Ordering information F SCAN5 Product id...

Page 2: ...frequency value 13 The properties of frequencies 13 The menu DUO 14 How to start pause or stop a program 16 The menu SWEEP 17 The menu DIRP 18 How to prepare for a DIRP and run it 20 EAP ELECTRO ACUPU...

Page 3: ...ith 4 generators Special accessories like the UV Flat Magnetic Coil Adapter can be connected to the Pow erPort w ithout a separate amplifier The intensity of the sine w ave and square w ave signals d...

Page 4: ...a procedure that has been developed by TB Electronics This feature can be used to adjust output signal to the application in real time The very sensitive measuring method that is used in this procedu...

Page 5: ...ith instruction manual FTB135 Wall charger FTB224 Stainless steel electrodes FTB202A Application cable for electrodes FTB308 5 sets of self adhesive pad electrodes FTB041 DIRP sensor FTB303 USB cable...

Page 6: ...6 Elements for operation A touch on this icon switches the unit OFF CON2 WIDE output port 15MHz CON2 WIDE Mini USB connector CON1 Multi signal output port CON3 PowerPort ON switch Slot for ChipCard...

Page 7: ...uctivity measurement The channels that are currently in use are indicated in the DUO mode menu Signal forms delivered to Multi signal output port SINE DC OFFSET 10Vpp Vpp SQUARE 0 symmetrical Full Wav...

Page 8: ...e connected Connector 3 5mm CON2 At this connector is the WIDE output available w ith a bandw idth up to 15 MHz Standard application parts may be connected Connector 2 5mm on CON3 Connector for the Po...

Page 9: ...isplayed means SERIAL Serial number of device ONS Number of uses Ds Number of DIRPs FLASH ID identifies the type of internal memory FFFFFFFF w ould indicate a memory defect The device must then be che...

Page 10: ...igned to each frequency value Run time TIME Signal form Auto Sine Square Half Wave Square Full Wave SMA RT and OFF WOBBLE Output sw ings around the target frequency ENV ELOP Amplitude oscillates betw...

Page 11: ...ith 03 00 3 minutes and 0 seconds the signal form selected AUTO the icons WOBBLE and ENV ELOP remain inactive their background is w hite How to select a program from the menu 123 A touch on the progr...

Page 12: ...O copies the selected program to the DUO section so that a standard single channel program can also be used as DUO TRIPLE or QUA D application To close the copy paste cut sub men press the X icon top...

Page 13: ...time The factory setting of the runtime per frequency is 3 00 minutes It can be changed after a touch on the above icon and the input of the minutes and seconds to be applied A touch on the ENTER key...

Page 14: ...image indicates four channels and the red black green yellow and blue output plugs on the screen show where to connect the application parts NOTE the blue plug is used for conductivity measurement and...

Page 15: ...d proceed w ith the intended function COPY copies the entry into the paste buffer PASTE copies the contents of the paste buffer into a selected memory position CUT deletes the entry COPY TO 123 copies...

Page 16: ...ude slider and current indicator are displayed differently The amplitude cannot be modified any more As long as the current measuring system does not see a valid current flow ing the amplitude is set...

Page 17: ...al form is AUTO w hich means SQUARE DC OFFSET through 65000 Hz and SINE above that value The amplitude is as selected in menu 123 If OSCA is set the amplitude is set to 60 To modify the amplitude OSCA...

Page 18: ...king on the right side of the screen indicates the output that has to be used with the finger sensor FTB303 The analysis is based on tw o readings 1 MV Measured Value of a resonance 2 CV Conductivity...

Page 19: ...m the remaining graph You can use the arrows to load a program Touch to move w ithin the graph in the direction of Fmin to read the CV MV and CL of individual resonances Touch to move w ithin the grap...

Page 20: ...d black and blue circles 2 Connect the red wire to the cylinder Hold the cylinder in the left hand 3 Touch the button START to start the analysis 4 Wait until the graph line reaches Fmax and completes...

Page 21: ...ect the EA P cable to the sensor port of the F SCA N5 on the left side of the device Connect the EA P Stylus to the blue lead of the EAP cable Connect a handheld or foot electrodew ith the red lead of...

Page 22: ...ime The measured value show n under the table block must have returned to 00 before the next point can be measured All measured values betw een 45 and 55 are considered to be w ithin the NORMAL RANGE...

Page 23: ...hogen list w ith associated frequencies The list is memorized in a nonvolatile memory and simple procedures for computer experts to dow nload updated or individual lists exist The idea of SUB SCAN is...

Page 24: ...ttons w ill have no effect All other buttons can be used as described in the DIRP chapter After a SUB SCA N procedure also know n as selective DIRP all frequencies that belong to a group are filtered...

Page 25: ...w ords are indicated in the selected language For other languages the ABC list entries are also translated EA P SENSE set this slider to the desired sensitivity The standard setting is 20 6 The value...

Page 26: ...to low est possible setting after 30 seconds Any touch on the screen sets the backlight to its preset value The pow er save function saves battery charge during an application so that it is possible...

Page 27: ...ets previously stored in program positions in the F SCAN5 w ill be lost Touch the third line to store the frequency values of the program position presently open in the F SCAN5 on the ChipCard for use...

Page 28: ...GRA MM 1 10 100 1000 10000 PROGRA MM 2 20 30 40 50 60 100 The program name maximum of 20 characters letters of the alphabet only must be set in parenthesis It is follow ed by 1 to 30 frequency values...

Page 29: ...ments to frequencies offered there are applicable The altered program can thus be transferred to other F SCAN models w ith the help of the ChipCard How to start pause or stop a program Touch the icon...

Page 30: ...wave Amplitude 0 to 24Vpp Square signal per manent positive DC OFFSET Amplitude 0 to 12Vpp Frequency range Sine 1Hz to 3 MHz Square guaranteed to100 kHz See list below for typical dependency of ampli...

Page 31: ...rking F SCAN4 Frequency Synthesizer in alleiniger Verantwortung auf dass sich diese Erkl rung bezieht mit der folgenden Norm bereinstimmt declare under our sole responsibility to which this declaratio...