33

34

CAMERA ADJUSTMENT

CAMERA ADJUSTMENT

 

 

ON: Make motion areas visible, OFF: Hide motion areas 

 

 

ENABLE

  Press enter to access the 

“dead band setting”

 

 

screen, on-screen cursor moves in response to the

 

 

inputs Left, Right, Up and Down to set the sensing area, 

 

 

or dead band for speciied blocks. This allows you to 

 

 

specify and set an area of motion which is not

 

 

rectangular in shape. 

 

 

Press and hold SET button 3 seconds to exit.

MOTION AREA: 

ON / OFF Enable / Disable Area No.

AREA SEL:  1/4 / 2/4 / 3/4 / 4/4. Selects motion area number.

TOP: 

Set the top side of the monitoring frame selected by the AREA SEL

 

parameter.

BOTTOM:  Set the bottom side of the monitoring frame selected by the AREA
 

SEL parameter

LEFT: 

Set the left side of the monitoring frame selected by the AREA SEL

 

parameter.

RIGHT: 

Sets the right side of the monitoring frame selected by the AREA SEL

 

parameter

CAMERA ID

 

OFF / ON

Camera ID shows a name on the screen as chosen.

 

CAMERA TITLE SETUP

   CAMERA  
 
 
ABCDEFGHIJKLMNOPQRSTUV 
WXYZ0123456789-!#$%&’ 
()_`.:;<=>

 

@^*./^*X+/ 

               CHR1   CHR2

 

         



  CLR POS

 

RETURN

Use Up/Down/Left/Right to move around. CHR1/2 changes the selection fonts to 
alternative selection, CLR will clear info. POS allows position change.

LL

PHASE 

326

 
 
 
 
 
 
 
RETURN

SYNC

 

 

INT / LL 

 

Video synchronization displayed

 

INT(Internal) or LL (Line Lock)

 

Note:

 Shows 

INT

 with DC only model.

 

And 

LL

 setting for camera model

 

when connected to a AC supply.

PHASE: 

000-524

 

Adjust the phase in the vertical direction when the line

 

lock mode is available. 

CAMERA RESET

 

 

 

 

This will reset all settings for all menus  to manufacturer

 

defaults. This allow you to return to shipped settings

 

from the manufacturer.

EXIT / SAVE ALL

 

• 

EXIT  

Exit OSD menu.

• 

SAVE ALL 

Saves the settings to camera

Refer to the following table if you are experiencing trouble with your camera. 

Summary of Contents for TBK-MD5720EIRV

Page 1: ...TBK MD5720EIRV Dome Camera ICR Day Nigth Smart IR Varifocal Lens User Manual TBK MD5720EIRV...

Page 2: ...g recess mount use screwdriver will lock lungs into place and also adjust Dimensions of hole must be within speciications as show on Mechanical Drawing 4 Reit is matter of put dome into recess and tur...

Page 3: ...setup menu Main setup menu is displayed on the monitor screen SETUP MENU SETUP MENU LANGUAGE ENGLISH LENS AUTO SHUTTER AGC AUTO WHITE BAL ATW DAY NIGHT AUTO PICT ADJUST 2DNR NEXT EXIT SAVE ALL Select...

Page 4: ...open position Default setting is Auto SPEED 000 255 Sets the convergence speed of the mechanical iris Default setting is 80 SHUTTER AGC SETUP MENU LANGUAGE ENGLISH LENS AUTO SHUTTER AGC AUTO WHITE BA...

Page 5: ...OR RETURN SPEED 000 255 Speciies the AE control for ATW Default setting is 239 DELAY CNT 000 255 Sets the time based of ATW change Default setting is 16 ATW FRAME x0 50 x1 00 x1 50 x2 00 Sets pull in...

Page 6: ...r only DAY NIGHT BURST ON DELAY CNT 10 DAY NIGHT 3 NIGHT DAY 5 RETURN BURST ON OFF Selects whether to output the burst signal when night mode has been identiied DELAY CNT 000 255 Night Day identiicati...

Page 7: ...WHITE BAL ATW DAY NIGHT AUTO PICT ADJUST 2DNR Digital Noise Reduction This function reduces the background noise in a low luminance environment NR MODE Y C OFF Y C Noise reduction Filter mode Y LEVEL...

Page 8: ...the top side of the mask frame selected by the AREA SEL parameter BOTTOM Sets the bottom side of the mask frame selected by the AREA SEL parameter LEFT Sets the left side of the mask frame selected by...

Page 9: ...ets the right side of the monitoring frame selected by the AREA SEL parameter CAMERA ID OFF ON Camera ID shows a name on the screen as chosen CAMERA TITLE SETUP CAMERA ABCDEFGHIJKLMNOPQRSTUV WXYZ01234...

Reviews: