TBK-NVR2100 Network Video Recorder User Manual V2
155
Check the brand, model of the switch connecting IP camera and NVR, and
contact with the manufacturer of the switch to check if it has the function of
flow control. If so, please turn it down.
Check if the fault is solved by the step 1 to step 4.
If it is solved, finish the process.
If not, please contact the engineer from our company to do the further
process.
No monitor connected with the NVR locally and when you manage the IP camera to
connect with the device by web browser remotely, of which the status displays as
Connected. And then you connect the device with the monitor via VGA or HDMI
TM
interface and reboot the device, there is black screen with the mouse cursor.
Connect the NVR with the monitor before startup via VGA or HDMI
TM
interface, and
manage the IP camera to connect with the device locally or remotely, the status of
IP camera displays as Connect.
Possible Reasons:
After connecting the IP camera to the NVR, the image is output via the main spot
interface by default.
Enable the output channel.
Select “Menu > Configuration > Live View > View”, and select video output
interface in the drop-down list and configure the window you want to view.
⚫
The view settings can only be configured by the local operation of NVR.
⚫
Different camera orders and window-division modes can be set for different
output interfaces separately, and digits like “D1”and “D2” stands for the
channel number, and “X” means the selected window has no image output.
Check if the fault is solved by the above steps.
If it is solved, finish the process.
If not, please contact the engineer from our company to do the further
process.
Live view stuck when video output locally.
Possible Reasons: