background image

 
 

TBS Installation Manual 

 

3D FLASH+

 

 

TBS 3D FLASH+ Mounting and Installation Guideline    

    TBS-061    

    Rev 11-2023

  

page 15 of 17

 

 

400 

General HW error. 

 

401 

Intrusion detected. 

Resolve using DeviceConfig under Maintenance / Security 
/ Intrusion Prevention page. 

410 

Unknown sensor error. 

 

411 

Sensor lost from USB interface. 

 

412 

Sensor  incorrect  behaviour  -  sensor 
thread stops etc. 

 

413 

Wrong sensor configuration. 

 

414 

Runtime sensor error. 

 

415 

Sensor too long in pos. loop three times 
in row. 

The sensor is continuously triggered either manually or by 
external  light  or  object  inside  sensor  cavity.  Rectify  the 
cause and re-power the device. 

420 

Unknown RFID error. 

 

421 

RFID initialization failed. 

Ensure that RFID module is connected. 

422 

RFID  runtime  error  (e.g.  communication 
with reader failed). 

Shutdown and re-power the device. 

423 

RFID card reading error. 

 

430 

Unknown Relay/GPIO error 

 

431 

Relay/GPIO communication error 

 

440 

General 

problem 

with 

external 

verification  initiated  from  3rd  party 
software. 

 

441 

Empty  token  comes  from  external 
device. 

 

500 

General logic error. 

 

501 

User  presented  card  in  smartmode  and 
he does not have it allowed. 

Enable RFID flag in 'Id factors' for user in BioManager. 

600 

Unknown profile set. 

 

601 

Wrong profile configuration. 

 

602 

Communication error in profile (e.g. with 
SmartController). 

 

701 

Too  many  pending  access  infos  (TnA 
records)  in  the  cache  (device  offline  for 
long time). 

Verify the connection to XML or WE server. 

702 

Enrollment  error  appeared  (e.g.  due  to 
UserID duplication reported by server). 

Delete error user in Admin DB page and ensure duplicate 
UserID or PIN code is not enrolled again. 

703 

One or more enrollments are pending on 
device (device is offline). 

Verify the connection to WE server. 

800 

Too  old  BSP  version  for  current  FW  or 
BSP Unknown reported. 

 

900 

Unknown (general) camera error. 

 

901 

Camera service communication error. 

Verify camera endpoint configuration in DeviceConfig and 
ensure camera service is running on server. 

1000 

General network error. 

 

1001 

No Wifi signal. 

 

1002 

Low Wifi signal. 

 

 

 

 

 

Summary of Contents for 3D FLASH+

Page 1: ...ocument TBS 061 NOTE The latest version of this document always available at https cloud1 tbs biometrics com index php s TWldCHnZtkRn0LV Release Author Comment July 15 2023 AG First version Nov 01 202...

Page 2: ...7 3 5 Installation with Backunit 8 3 6 Installation with Fingerprint Recognition Sensor 8 4 Power and Signal Wiring 9 4 1 3D FLASH Wiring Layout and Cables 9 4 2 General Wiring Requirements 11 4 3 Pow...

Page 3: ...figuration options on the market This document describes the mounting and installation of the 3D FLASH As an optional add on a Fingerprint sensor can be attached to the base reader The installation of...

Page 4: ...als or attending TBS trainings webinars When not otherwise stated the following safety instructions apply Installation and servicing of our appliances must be carried out when disconnected from the po...

Page 5: ...d Sunlight halogen lamps or other strong illumination may reduce the performance of the 3D FLASH and may result in increased failure to capture rates or failed authentication events The 3D FLASH was d...

Page 6: ...en protrude further from the wall allowing for ventilation This version is recommended if a further upgrade with the fingerprint sensor module could be considered by the customer The metallic wall pla...

Page 7: ...atches the opening in the wall Utilization of wall anchors is mandatory To mount 3D FLASH slide the 3D FLASH into the wall plate from the top Lock the 3D FLASH using the two M3 x 6mm screws on bottom...

Page 8: ...steps for a new installation are 1 Install the FRS to the wall The backunit supplied with the 3D FLASH is not required 2 Install the metal wall plate on the FRS with 6 screws 3 Connect the USB plug f...

Page 9: ...ation Guideline TBS 061 Rev 11 2023 page 9 of 17 4 Power and Signal Wiring 4 1 3D FLASH Wiring Layout and Cables This chapter describes the general wiring layout and the cables provided with the devic...

Page 10: ...TBS Installation Manual 3D FLASH TBS 3D FLASH Mounting and Installation Guideline TBS 061 Rev 11 2023 page 10 of 17...

Page 11: ...des 15 VDC 4A 60 W PSU is included with the device IMPORTANT Use stable power supply and shorter power input cable if possible with correct gauge wire Any over or under voltage applied to this unit ma...

Page 12: ...ing peripheral devices the cable should be of Cat5 or higher it does not need to be crossed 4 5 Integrated Relay Depending on the 3D FLASH input voltage set Switch 4 position to choose from 12 or 24 V...

Page 13: ...V Offset IO A Data In Out 0V 5V Bias 7 V Offset For farthest terminal a 120 Ohm resistor termination may be added outside the terminal between IO and IO 4 7 2 RS232 Serial Interface Please connect fro...

Page 14: ...ts with dust or where oily substances are handled or other extraordinary environmental factors are present the sensor surfaces need to be checked and cleaned with increased frequency Replacement Parts...

Page 15: ...eral problem with external verification initiated from 3rd party software 441 Empty token comes from external device 500 General logic error 501 User presented card in smartmode and he does not have i...

Page 16: ...tion channel BME installer sets required firewall settings by default Yes No Biometric Client Service PC BME channel 1 8808 HTTPS communication channel to BME server and Device Control Center DCC No Y...

Page 17: ...artner Portal with full product documentations and access to latest firmware for terminals Access is restricted to registered TBS Partners TBS System Requirements Permanent link https cloud1 tbs biome...

Reviews: