Loudness Max –

 The maximum short-term loudness measurement throughout 

your material. 

Loudness Range –

 Your overall program material range from the softest point 

to the loudest. 

Peak to Loudness –

  Indicates the 'squash' factor/ratio of your overall material. 

Sliding 10 sec –

 The maximum loudness measurement within  

a 10 second window. 

Balance-O-Meter

This innovative new meter allows quick visual feedback of the left-right and 

mid-side balances of your mix. It can be activated by entering the Edit menu 

and pressing the Layout button, then using the arrow buttons to select a location 

where you want the Balance-O-Meter to appear. Turn the rotary wheel 

(Adjust) to select this meter. Note that it will take up 2 slots in the Loudness 

Descriptors list.

The top of the triangle will point toward the top/center of the semi circle when a 

perfect left-right balance is achieved. The width is indicated by how broad the 

base of the triangle is. 

A wide, center-balanced mix will appear as a symmetrical triangle. 

The top point will tilt either direction as the channels become less balanced, and 

the base will appear narrower to indicate less width. 

A center-balanced mono signal with no width will appear as a single line.

Source Section

Above the descriptors is a display for the current audio source. A square box in 

front of the source name will indicate the status of the connection. Red means no 

connection (No Digital Lock), and green indicates successful connection  

(Digital Lock).

Digital Inputs

When you use digital inputs, AES or Optical, the type of connection is displayed. 

Options are AES 1, 2, 3, 1-3 (5.1 surround), and Optical. The Stereo model does not 

support AES 1-3.

Plug-in Mode

When using the plug-in as input (USB Mode set to Plug-in), the source section can 

display the name and number of the track or bus where the plug-in is inserted in 

the DAW. 

To change the source, access the System (SYS) menu. Beware that changing the 

source causes the meters to reset automatically. 

True-Peak Meter

Based on TC Electronic's highly-acclaimed true-peak technology, the True-Peak 

Meter identifies potential clipping in codecs and digital-to-analog converters and 

helps you avoid unwanted distortion.
The True-Peak Meter can alternatively be set to occupy the full screen height 

by accessing the Edit menu and pressing the Layout button (see Chapter 7). 

There are many PPM standard meter layouts available.

Summary of Contents for Clarity M

Page 1: ...User Manual CLARITY M CLARITY M STEREO Desktop Audio Meter with 7 High Resolution Display and USB Connection for Plug In Metering 2018 09 27 Version 2 0...

Page 2: ...Legal Disclaimer 3 Limited warranty 3 1 Introduction 4 2 Mounting 4 3 Hook up 4 4 Controls and Connectors 8 5 SUB D Cable 9 6 General Operation 9 7 Editing Presets 12 8 Library 14 9 System 15 10 Plug...

Page 3: ...tusduringlightningstormsor whenunusedforlongperiodsoftime 14 Referallservicingtoqualifiedservicepersonnel Servicingisrequiredwhentheapparatushasbeen damagedinanyway suchaspowersupplycordorplug isdamag...

Page 4: ...audio on 75 Ohm BNC connectors for broadcast grade 5 1 metering and stereo optical for maximum flexibility Continue through this manual to learn about the functionality and operation of the Clarity M...

Page 5: ...ion for firmware updates and preset exchange Included cable that goes from SUB D 15 to 3 AES unbalanced inputs on BNC female connectors plus a stereo 2 GPI and 1 8 mono GPO connector Connect to an ext...

Page 6: ...diointerface digitalS PDIFinput USB connection for firmware updates and preset exchange Custom SUB D 15 cable with included BNC to RCA adapter connects to the S PDIF output of an audio interface Stere...

Page 7: ...ce digitalTOSinput GPIO USB connection for firmware updates and preset exchange Indication of peaks or overloads to external equipment Optical TOS cable Audio interface 2 button footswitch for Play Pa...

Page 8: ...ence and measurements below 0 indicate out of phase material 6 Adjustment knob allows various parameters to be controlled 7 These selection buttons access the corresponding functions listed in the LCD...

Page 9: ...ickly when you adjust your mix making it a helpful indicator of where your loudness is in relation to the target value 6 7 8 1 2 3 5 4 Press the 1st button to start or pause the loudness measurement T...

Page 10: ...e Loudness Descriptors Section Regardless of the Main Section view on the left side the screen will show various levels and metering feedback on the right hand side of the screen This information can...

Page 11: ...lanced and the base will appear narrower to indicate less width A center balanced mono signal with no width will appear as a single line Source Section Above the descriptors is a display for the curre...

Page 12: ...left surround right surround with 2 bar graphs Phase issues can result in audible loss of low frequencies unintended alterations to a mix among many other problems Readings toward the positive end of...

Page 13: ...um or compensated level 3 dB Sum is intended for specific broadcast situations where for example a mono signal is presented in both left and right channels 22 Sets the Loudness metric used for the Dev...

Page 14: ...dicated folder will appear for those files Preset names have the following structure _NAME indicates 2 digits such as 06 for preset 6 and an underscore must be placed between the number and name with...

Page 15: ...B Mode is set to Plug in the input will automatically be changed to Plug in Note that changing the input causes the meters to reset 3 In case you work in surround this parameter determines in which or...

Page 16: ...ents you want to install Only select the 64 bit versions if you run a 64 bit system Pro Tools uses AAX and most other DAW programs use VST Select the install location for each of the plug ins and choo...

Page 17: ...ompanied by Connecting text All other connection problems are indicated by a red circle This could be happen if the USB cable is disconnected the Clarity M unit is powered off USB Mode is set to Disk...

Page 18: ...or further instructions on how to make offline processing in that DAW When Clarity M goes into offline mode a pre set fixed screen layout will be displayed Only metering types that are relevant for of...

Page 19: ...A 12 V DC 0 5 A Physical Dimensions H x W x D 140 x 182 x 38 mm 5 5 x 7 2 x 1 5 140 x 182 x 38 mm 5 5 x 7 2 x 1 5 Weight 1 2 kg 2 6 lbs 1 2 kg 2 6 lbs Accessories Included Accessories 2 5 mm HEX key 2...

Page 20: ......

Reviews: