background image

15

CLARITY M/CLARITY M STEREO User Manual

Screenshots

Press buttons 1 and 3 simultaneously to create a screenshot. A prompt will allow 

you to cancel or confirm the screenshot. If you are connected to a computer, eject 

Clarity M before confirming. The image will appear in the Screenshots folder 

when connected to a computer.

9.  System

Press the 5th button to access the System menu. This allows several global 

adjustments and preferences to be set.

1.  When the Clarity M is connected to a computer via USB, it can operate in two 

modes (USB Modes):

Disk Drive Mode

 

Use this setting to:
 - Organize presets: Rename, copy, delete or move 

- Add your company's logo to the front screen of Clarity M 

- Transfer screenshots from Clarity M to your computer’s hard drive 

- Update firmware
 

Plug-in Mode

 

Use Plug-in Mode if you want to use the Clarity M plug-in as a sound source 

for the Clarity M meter.
 When switching from Disk Drive mode to Plug-in Mode, Clarity M will no 

longer be a USB drive, and to prevent data loss you will be prompted to use 

the eject feature of your computer to eject the Clarity M USB Drive from  

your computer.

2.  Select the input source. When using digital inputs, AES or optical, the options 

are AES 1, 2, 3, 1-3 (5.1 surround*

2

), and optical. When USB Mode is set to  

Plug-in, the input will automatically be changed to Plug-in. Note that  

changing the input causes the meters to reset. 

3.  In case you work in surround, this parameter determines in which order the 

channels are displayed. This parameter has no effect on the routing of the 

channels; the audio channel routing of Clarity M is fixed to the ITU routing 

matrix (L-R-C-LFE-LS-RS). It affects only the order the channels are displayed.  

The options are:
Film: L-C-R-LS-RS-LFE  

ITU: L-R-C-LFE-LS-RS 

This feature does not apply to the Stereo model.

4.  Select the function of the rotary knob when using the radar meter.

*The Stereo model does not support surround.

5.  Select the function of GPI 1 and 2. Each can trigger pause or reset commands 

from a remote device.

6.  Select the function of the GPO. This can send either the Peak, Loud, or  'Peak 

or Loud' indications to an external device. See Chapter 6 - Radar section 

for details. 

7.  Adjust the LCD brightness.
8.  Adjust the LCD contract.
9.  Scroll through a list of system information.
10.   View the relevant FCC and CE compliance information by scrolling with  

the rotary knob. 

10.  Plug-in Metering

Download the Clarity M plug-in installer from  

tcelectronic.com/p/P0C7T/Downloads

Installation on a Mac

Open the zip folder and double click the installer icon.

Proceed through the prompts, accept the license agreement and  

begin installation.

Installation on PC

Open the zip folder and double click the executable file. 

Summary of Contents for Clarity M

Page 1: ...User Manual CLARITY M CLARITY M STEREO Desktop Audio Meter with 7 High Resolution Display and USB Connection for Plug In Metering 2018 09 27 Version 2 0...

Page 2: ...Legal Disclaimer 3 Limited warranty 3 1 Introduction 4 2 Mounting 4 3 Hook up 4 4 Controls and Connectors 8 5 SUB D Cable 9 6 General Operation 9 7 Editing Presets 12 8 Library 14 9 System 15 10 Plug...

Page 3: ...tusduringlightningstormsor whenunusedforlongperiodsoftime 14 Referallservicingtoqualifiedservicepersonnel Servicingisrequiredwhentheapparatushasbeen damagedinanyway suchaspowersupplycordorplug isdamag...

Page 4: ...audio on 75 Ohm BNC connectors for broadcast grade 5 1 metering and stereo optical for maximum flexibility Continue through this manual to learn about the functionality and operation of the Clarity M...

Page 5: ...ion for firmware updates and preset exchange Included cable that goes from SUB D 15 to 3 AES unbalanced inputs on BNC female connectors plus a stereo 2 GPI and 1 8 mono GPO connector Connect to an ext...

Page 6: ...diointerface digitalS PDIFinput USB connection for firmware updates and preset exchange Custom SUB D 15 cable with included BNC to RCA adapter connects to the S PDIF output of an audio interface Stere...

Page 7: ...ce digitalTOSinput GPIO USB connection for firmware updates and preset exchange Indication of peaks or overloads to external equipment Optical TOS cable Audio interface 2 button footswitch for Play Pa...

Page 8: ...ence and measurements below 0 indicate out of phase material 6 Adjustment knob allows various parameters to be controlled 7 These selection buttons access the corresponding functions listed in the LCD...

Page 9: ...ickly when you adjust your mix making it a helpful indicator of where your loudness is in relation to the target value 6 7 8 1 2 3 5 4 Press the 1st button to start or pause the loudness measurement T...

Page 10: ...e Loudness Descriptors Section Regardless of the Main Section view on the left side the screen will show various levels and metering feedback on the right hand side of the screen This information can...

Page 11: ...lanced and the base will appear narrower to indicate less width A center balanced mono signal with no width will appear as a single line Source Section Above the descriptors is a display for the curre...

Page 12: ...left surround right surround with 2 bar graphs Phase issues can result in audible loss of low frequencies unintended alterations to a mix among many other problems Readings toward the positive end of...

Page 13: ...um or compensated level 3 dB Sum is intended for specific broadcast situations where for example a mono signal is presented in both left and right channels 22 Sets the Loudness metric used for the Dev...

Page 14: ...dicated folder will appear for those files Preset names have the following structure _NAME indicates 2 digits such as 06 for preset 6 and an underscore must be placed between the number and name with...

Page 15: ...B Mode is set to Plug in the input will automatically be changed to Plug in Note that changing the input causes the meters to reset 3 In case you work in surround this parameter determines in which or...

Page 16: ...ents you want to install Only select the 64 bit versions if you run a 64 bit system Pro Tools uses AAX and most other DAW programs use VST Select the install location for each of the plug ins and choo...

Page 17: ...ompanied by Connecting text All other connection problems are indicated by a red circle This could be happen if the USB cable is disconnected the Clarity M unit is powered off USB Mode is set to Disk...

Page 18: ...or further instructions on how to make offline processing in that DAW When Clarity M goes into offline mode a pre set fixed screen layout will be displayed Only metering types that are relevant for of...

Page 19: ...A 12 V DC 0 5 A Physical Dimensions H x W x D 140 x 182 x 38 mm 5 5 x 7 2 x 1 5 140 x 182 x 38 mm 5 5 x 7 2 x 1 5 Weight 1 2 kg 2 6 lbs 1 2 kg 2 6 lbs Accessories Included Accessories 2 5 mm HEX key 2...

Page 20: ......

Reviews: