FRONT PANEL KEYS AND FUNCTIONS 

UTILITY

dB

dB

dB

-

dB

-

-20

LEFT INPUT

RIGHT INPUT

RIGHT OUTPUT

LEFT OUTPUT

PPM dB

TC 1280 STEREO DIGITAL AUDIO DELAY

0

0

-10

-6

-3

-10

+10

+10

+6

-6

+6

+3

+3

-3

-3

-9

-9

-20

-12

-0

-6

-0

8

8

-3 -20

-6

-12

mSec.

parameter

-3

-10

+3

0

OVERLOAD

0 SOFTWARE VERSION
1 RESOLUTION (microsec./frames)
2 MIDI DEVICE/CHANNEL NO.
3 RESET
4 DISTANCE MODE
5 SECURITY LOCK
6 PRESET SELECT
7 LAST ERROR
8 MIDI ERROR CORRECTION 

METRE

VALUE

PARAM.

UTILITY

SHOW DISTANCE

POWER

DELAY

BYPASS

value

uSec.

R

L=R

L

DELAY

DELAY

MONO

FEET

MUTE

LINE

DOWN

UTILITY LIST

UP

 

 
<POWER> 

Mains power on/off switch. During start up, the unit will display the 
software revision number. Note: the audio signal input is connected 
directly to the output by a relay when power is not on.  
 

LEFT INPUT 

Input gain of left channel. -10dB to +10dB. 
 

RIGHT INPUT 

Input gain of right channel. -10 dB to + 10 dB.  
 

LEFT OUTPUT 

Output volume of left channel. 0dB to mute  
 

RIGHT OUTPUT 

Output volume of right channel. 0dB to mute  
 

PPM 

Peak program meter for both left and right channels. When "DELAY 
LINE" is adjusted for left, the PPM will display the left channel. 
When "DELAY LINE" is adjusting for right, the meter will display the 
right channel. When "DELAY LINE" is adjusted to L= R (left = right) 
the PPM will display the audio channel which is highest.  
 

OVERLOAD 

The OVERLOAD LED +3 will 

always

 display a overload on either 

left or right channel. 
 

BYPASS 

Delay bypass on left and right channels. Sets the delay time to 0 
seconds. (This is not a relay bypass)  
 

MUTE 

Mutes both channels at output.  
 

MONO 

Mixes left and right inputs to a mono signal.  
 

DELAY LINE 

Switches between 3 positions L, R or L=R. Left channel (L) displays 
the delay time of left channel. Right channel (R) displays the delay 
time of right channel. Left = right (L= R) displays the delay time of 
both channels alternatively.  
 

DELAY DOWN 

Decreases delay time for the displayed channel 
(or both if L=R displayed).  
 

DELAY UP 

Increases delay time for the displayed channel 
(or both if L=R displayed).  
 

SHOW DISTANCE 
METRE  

Press the "DELAY LINE" and the "BYPASS" keys simultaneously in 
order to get the delay displayed in meters. Press the "DELAY LINE" 
or "DELAY UP" / "DELAY DOWN" to get back to time display. 
 

Note: If UTILITY PARAMETER 4 is set to VALUE 1 you can adjust 
the delay time in SHOW DISTANCE mode 

 

SHOW DISTANCE 
FEET 

As above, but press the "DELAY LINE" and the "MUTE" keys 
simultaneously in order to get the delay displayed in feet. 
 

UTILITY 

Please refer to UTILITY FEATURES. 

 

Summary of Contents for TC 1280

Page 1: ...1 of 9 OWNERS MANUAL version 2 TC 1280 STEREO DIGITAL AUDIO DELAY Contents FEATURES FRONT PANEL AND FUNCTIONS PRESETS MIDI REMOTE UTILITY FEATURES REAR PANEL MEMORY EXPANSION ERROR MESSAGES DISTANCE...

Page 2: ...No degradation of signal quality The TC digital converter technology has been acclaimed as being very musical and warm Soft HF roll off 3dB 25 kHz and 12 dB 33 kHz allows ALL the signal to pass thru...

Page 3: ...splay the left channel When DELAY LINE is adjusting for right the meter will display the right channel When DELAY LINE is adjusted to L R left right the PPM will display the audio channel which is hig...

Page 4: ...equipment MIDI Set the UTILITY PARAMETER 2 to the appropriate MIDI channel device number Recall the desired preset by MIDI program change command The bypass status of the TC1280 can be set with MIDI C...

Page 5: ...hen select the parameter number by pressing the up down keys VALUE Press DELAY LINE and VALUE simultaneously to access the utility value number Then select the value number by pressing the up down key...

Page 6: ...NO OUT Mono output Sum of left and right inputs after input gain L OUT left output Left channel output XLR balanced pin 2 hot R OUT right output Right channel output XLR balanced pin 2 hot REMOTE TC 0...

Page 7: ...ctions will come with the option ERROR MESSAGES The last error message number will be displayed if UTILITY 7 is selected The values mean the following VALUE DESCRIPTION 13 The unit has made a reset 15...

Page 8: ...2 9 344 1 345 4 346 7 348 0 349 2 350 6 80 339 3 340 5 341 8 343 1 344 4 345 7 347 0 348 3 349 7 351 0 Temp 12 C 14 C 16 C 18 C 20 C 22 C 24 C 26 C 28 C 30 C Humidity 53 6 F 57 2 C 60 8 C 64 4 F 68 F...

Page 9: ...CE MIDI In Out 5 Pin DIN SYSEX implemented Remote 1 4 phone jack GENERAL EMC Complies with EN 55103 1 EN 55103 2 FCC part 15 class B CISPR 22 class B SAFETY Complies with IEC 65 EN 60065 Operating Tem...

Reviews: