 REAR PANEL 

OUT

220 - 240V: T250mA

100 - 120V: T400mA

TYPE : TC 1280

NO.

SERIAL

FUSE :

IN

30W/  50-60 Hz

MIDI

S

REMOTE

R

OUT

L

OUT

MONO

OUT

R

L

IN

IN

PUSH

PUSH

GROUND
     LIFT

 

L IN (left input) 

Left channel input. XLR balanced, pin 2 hot. 
 

R IN (right input) 

Right channel input. XLR balanced, pin 2 hot. 
 

MONO OUT 

Mono output: Sum of left and right inputs after input gain. 
 

L OUT (left output) 

Left channel output, XLR balanced, pin 2 hot. 
 

R OUT (right output) 

Right channel output, XLR balanced, pin 2 hot. 
 

REMOTE 

TC 0050 remote input. Please refer to page 4. 
 

MIDI IN 

MIDI input. 
 

MIDI OUT 

MIDI output. 
 

GROUND LIFT 

Disconnects chassis from audio ground. 
 

FUSE 

External fuse holder, replace only with the correct type 
according to mains voltage. Please refer to rear panel.  
 

MAINS INLET 

IEC mains inlet. Make sure that the voltage selector and fuse 
type set correctly according to your mains supply. 

 

Summary of Contents for TC 1280

Page 1: ...1 of 9 OWNERS MANUAL version 2 TC 1280 STEREO DIGITAL AUDIO DELAY Contents FEATURES FRONT PANEL AND FUNCTIONS PRESETS MIDI REMOTE UTILITY FEATURES REAR PANEL MEMORY EXPANSION ERROR MESSAGES DISTANCE...

Page 2: ...No degradation of signal quality The TC digital converter technology has been acclaimed as being very musical and warm Soft HF roll off 3dB 25 kHz and 12 dB 33 kHz allows ALL the signal to pass thru...

Page 3: ...splay the left channel When DELAY LINE is adjusting for right the meter will display the right channel When DELAY LINE is adjusted to L R left right the PPM will display the audio channel which is hig...

Page 4: ...equipment MIDI Set the UTILITY PARAMETER 2 to the appropriate MIDI channel device number Recall the desired preset by MIDI program change command The bypass status of the TC1280 can be set with MIDI C...

Page 5: ...hen select the parameter number by pressing the up down keys VALUE Press DELAY LINE and VALUE simultaneously to access the utility value number Then select the value number by pressing the up down key...

Page 6: ...NO OUT Mono output Sum of left and right inputs after input gain L OUT left output Left channel output XLR balanced pin 2 hot R OUT right output Right channel output XLR balanced pin 2 hot REMOTE TC 0...

Page 7: ...ctions will come with the option ERROR MESSAGES The last error message number will be displayed if UTILITY 7 is selected The values mean the following VALUE DESCRIPTION 13 The unit has made a reset 15...

Page 8: ...2 9 344 1 345 4 346 7 348 0 349 2 350 6 80 339 3 340 5 341 8 343 1 344 4 345 7 347 0 348 3 349 7 351 0 Temp 12 C 14 C 16 C 18 C 20 C 22 C 24 C 26 C 28 C 30 C Humidity 53 6 F 57 2 C 60 8 C 64 4 F 68 F...

Page 9: ...CE MIDI In Out 5 Pin DIN SYSEX implemented Remote 1 4 phone jack GENERAL EMC Complies with EN 55103 1 EN 55103 2 FCC part 15 class B CISPR 22 class B SAFETY Complies with IEC 65 EN 60065 Operating Tem...

Reviews: