TXP Inst. & Maint. Manual: IM-825
17
Model
Max.
Frequency
Min.
Frequency
TXP
1016-
140
140 Hz
50 Hz
TXP
1212-
120
120 Hz
50 Hz
TXP
1313-
120
120 Hz
50 Hz
TXP
1414-
120
120 Hz
50 Hz
TXP
1614-
110
110 Hz
50 Hz
Device
with heat
shield
see device
type
50 Hz
Tab. 4: Permissible frequencies
Hazards from sharp edges, corners
and tips
CAUTION!
Risk of cutting due to
sharp edges, corners and
tips
Touching these areas can
lead to minor cuts.
Wear protective gloves
The impeller inside the fan has sharp
edges, corners and tips. Touching these
areas can lead to minor cuts. To avoid
these, the posts were deburred as far as
possible. In addition, the protective grille
on the suction opening prevents the
intervention in the housing and warning
signs on the fan warn of the danger.
Check the condition of these protective
measures regularly and replace them in
the event of damage.
Hazards due to the weight of the fans
During transport or installation of the
fan, there is a risk of the fan tipping over
or falling. In these situations, the fan is
not yet firmly screwed and its own
weight can injure people. Secure the fan
with suitable fasteners during transport
or installation and follow the instructions
in this manual.
2.7.2 Hazards from electrical en-
ergy
The electrical connection of the product
to the supply network as well as work on
the electrical equipment may only be
carried out by qualified electricians, con-
sidering the relevant standards and reg-
ulations.
The electrical components of the prod-
uct must be checked at regular intervals.
Defects, such as loose connections,
grated or simmered cables, must be rec-
tified immediately.
Keep moisture away from tension-carry-
ing parts. Moisture can cause short cir-
cuits.