TXP Inst. & Maint. Manual: IM-825
57
Model
Volume
flow*
Total Pressure
Difference*
Engine
Volt-
age
Fre-
quency
Power
Con-
sump-
tion
Engine
power at
max. per-
missble
speed
Weight
Sound
pressure
level
min/max
*1)
Ball Bearing
Designation
*2)
TXP 1414-
120/15
1600
48.6
7183
400
120
22.6
14.8
128
94/100
6306
TXP 1414-
120/20
2659
48.6
7185
400
120
21.7
20.1
181
94/103
6208
TXP 1614-
110/20
1642
54.9
6500
400
110
28.0
20.1
196
93/95
6208
TXP 1614-
110/25
2366
54.9
6510
400
110
34.0
24.8
212
93/95
6208
TXP 1614-
110/30
3189
54.9
6505
400
110
37.3
29.5
225
93/99
6208
Table 12: Specifications
The values in the table apply only to motors of Twin City Fan & Blower (other brands may vary).
*1)
min. value / max. value of the characteristic curve
*2)
-side / B-side standard designation
* Limit deviation according to DIN 24166 Accuracy class 3