2.11. Visual Mechanical inspection
Mechanical warranties check items:
1) Corrosion
Corrosion on the USB connectors, SIM connectors, and other metal surfaces
2) Hole
Holes (Diameter > 1mm) on any surface, including front casing, decorate frame, battery cover,
LCD Lens, keypad.
3) Bump
Bumps (Diameter>1mm) on any surface, including the front casing, decorate frame, battery cover,
LCD Lens, keypad
4) Scratch (length > 3mm)
Scratches on any surface, including the front casing, furnished frame, battery cover, LCD Lens,
keypad
5) Distortion
Bend, twisted or crushed on the h/s, cover/casing or connectors
6) Broken