11
Attaching Pump Drain Tube -
1.
Push in on the outer ring of the pump connector on the back of the dehumidifier (See photo).
2.
Slide the drain adapter into the opening and then release the outer ring of the pump connect.
3.
Gently pull the drain adapter to ensure it is locked into place.
4.
To remove the drain hose push in on the outer ring of the pump connector and pull on the
drain tube connector.
NOTE:
After the pump has been activated, the pump will not begin removing water until the internal
bucket is almost full and will continue removing water after this point until the pump mode is
turned off.
Makes sure there are not kinks or knots in the hose.
If there is a full tank alarm, please clean the tank first before activating the pump.
WARNING:
Before the ambient temperature drops to 32-degrees F (0-degrees C), condensate remaining in
the appliance must be emptied to avoid damage to the machine.
Make sure to clean the condensate channel every month to avoid damage to the pump by
unplugging the device, emptying the bucket and ensuring no blockage in the pump drain port.
Automatic Defrost -
When frost builds up on the evaporator coils, the compressor will stop and
the fan will continue to run until the frost disappears. When the coils are completely defrosted, the
compressor will automatically restart and dehumidify will resume. If the frost does not completely
melt on its own, unplug the appliance overnight. Be sure to confirm the filter is clean before