background image

TCNet Boiler Controller 

User and Service Manual 

17 

 

Changing the Network Settings 

Click the “Network Configuration” on menu box. 

 

Make all required changes on network configuration and click “Save Config” button.  

Please note that the controller should reboot after changing the network settings and perform the 
AC Power loss sequences at startup. 

 

 

Summary of Contents for Boiler Controller

Page 1: ...TCNet Boiler Controller User and Service Manual Developed and assembled in Turkey T rkiye de geli tirilmi ve retilmi tir...

Page 2: ...he temperature sensors may be extremely hot Caution Moving Parts Watch your hands while servicing the moving parts such as auger and grate cleaning assembly which may cause serious injuries Caution Th...

Page 3: ...TCNet Boiler Controller User and Service Manual 3 This page is intentionally left blank...

Page 4: ...Day Night Compensation 11 Date Time 12 Week Timer 12 Internet Connectivity 13 The Status Page 14 Adjust the Temperatures and Operation Mode From Internet 15 Setting up The Week Timer from Internet 16...

Page 5: ...TCNet Boiler Controller User and Service Manual 5 Overview to Control Panel 1 Power key 2 Input key 3 Menu navigation key 4 Menu navigation key 5 Decrease parameter key 6 Increase parameter key...

Page 6: ...ress the power key Setting up The Temperature of Boiler or Utility Water Press the Input key to enter the Temperature Setup menu Press navigation keys to highlight boiler temperature or utility water...

Page 7: ...ates the calculated output power of the boiler 4 Status display Indicates the current process of your boiler Ready Idle No operation or the boiler reached the set point temperature Flame check In this...

Page 8: ...ating I Ignition heater is operating C Cleaning mechanism is operating 7 Utility water circuit status display This section indicates the measured temperature of the utility water circuit icon indicate...

Page 9: ...up Basic temperature adjust of your boiler 2 User Preferences Operation mode timer and temperature compensation options 3 Service Settings Advanced settings of your boiler This settings are intended t...

Page 10: ...ble in the boiler system Weather Compensation Your boiler is able to adjust the temperature setpoint according to the weather temperature To setup the weather compensation first navigate to temperatur...

Page 11: ...ion keys and select the time slice with adjust keys After selecting the time slice navigate to Correction value and set the offset temperature of your boiler for this time slice To adjust another time...

Page 12: ...e insert the battery with correct polarity The overal life of backup battery is about two years The chemistry of the battery may be harmful to the environment Please dispose the old battery properly a...

Page 13: ...for connecting your boiler to your DSL modem router or computer The default IP address of your boiler is 192 168 1 127 If you have changed the IP address or enabled the DHCP service you may learn the...

Page 14: ...rvice Manual 14 After login you should see the status page of the boiler The Status Page All measured temperatures and the device status are shown on this page CPU load indicates the current utilizati...

Page 15: ...and Operation Mode From Internet Click the Temperature Setup on the menu box Adjust the temperatures and click Submit button If you don t want to make any adjustments click Administration from the men...

Page 16: ...ek Timer from Internet Click the Week Timer on menu box Set up your desired start up and shut down times for each day If you don t want to make any adjustments click Administration from the menu and c...

Page 17: ...rk Settings Click the Network Configuration on menu box Make all required changes on network configuration and click Save Config button Please note that the controller should reboot after changing the...

Page 18: ...Click Administration on menu box Click Turn On Boiler button to turn on your boiler Click Turn Off Boiler button to turn of your boiler Clearing Errors From Internet If you see any error messages on...

Page 19: ...ution This settings are intended to be adjusted by a well trained service technician or a service engineer Incorrect settings may cause dangerous conditions To enter the Service menu navigate to Servi...

Page 20: ...am of used pellet Please refer to the information on your pellet package Modulator PID The power regulation metod of the boiler There are three modes for power regulation PID Graph1 5STEP Graph2 or fi...

Page 21: ...odulation or Fixed power Mod1 5kW Fan 33 Mod2 10kW Fan 37 Mod3 15kW Fan 40 Mod4 20kW Fan 43 Mod5 25kW Fan 46 Exh Limit C 150 Maximum allowable flue temperature In case of flue gases exceed the limit c...

Page 22: ...never reaches the setpoint Increase the Mod1 Power level If your boiler exceeds the setpoint more than the hysteresis value Decrease the Mod1 Power Level If your heating circuit s power demand is too...

Page 23: ...Feed Period Ignition Data Feed Time sec 60 Timeout min 10 Retries 3 Burn Detect Temp C 100 Burn Detect Delta C 7 Graph5 Auger Filling min 3 First run 0 Fan Speed 50 Graph 5 Burning Detection and Defl...

Page 24: ...address of the controller Subnet Mask 255 255 255 0 The subnet mask of the controller Default Gateway 192 168 1 1 The default gateway address DSL modem router etc Pellet Refill Machine Type None Auge...

Page 25: ...l T2 Weather temp Sensor TC Flue temp Sensor Lambda sensor and photocell may not be implemented on your system Test Devices Warning This menu is only for testing the outputs of the boiler for a short...