Setup                                     

Note: 

If using remote sensor(s), the calibra-

tion may need to be adjusted. See “Checkout and 

Troubleshooting” section. 

TEMPERATURE SENSOR SELECTION

The dipswitches in the cover (shown above) must be 

set when using remote room, discharge, and/or outdoor 

sensors.  
Use the following guide to determine the dipswitch set-

tings for your application. 

   

 

Using built-in room sensor only.  

(This is the default setting.) 

   

 

Using built-in room sensor with 

discharge air sensor only. 

Using built-in room sensor with 

outdoor air sensor only.*

Using built-in room sensor with 

both discharge and outdoor air 

sensors.*

   

 

Using remote room sensor only.  

Using remote room sensor with 

discharge air sensor only. 

Using remote room sensor with 

outdoor air sensor only.*

Using remote room sensor with 

both discharge and outdoor air 

sensors.*

* (SZ1031 and SZ1035 only)

 

KEYPAD ACCESS

The dipswitches in the thermostat cover (shown above) 

must be set in order to lock the user out of the program 

and/or to set the clock and schedule.  Use the guide 

below to set these dipswitches for your application.  

User access may also be limited with an access code 

set in programming.  (The fan and system switches are 

enabled or disabled in programming only, and require no 

dipswitch placement.) 

Keypad access to both 

programming and clock setup.  

(This is the default setting.) 

No keypad access to programming 

or clock setup. 

 

Keypad access to 

programming only.
 

Keypad access to clock 

setup only. 

 

Once the dipswitches have been set 

and you have confirmed that the sen-

sors are reading correctly (and pro-

gram and clock setup are finished, if 

locking out access with dipswitches), secure the cover to 

the base with the two set screws located at the top right 

and the left side.

1  2  3  4  5 

1  2  3  4  5 

Summary of Contents for SZ1022

Page 1: ...or limited with the use of an access code Fahrenheit or Celsius temperature display Uses ZigBee protocol IEEE 802 15 4 compliant Self healing plug play mesh network 100mW output at 2 4 GHz 150 to 500...

Page 2: ...install a jumper between the R and 24 terminals The 24 terminal must then be connected to the common side of the unit transformer Wiring The SZ1022 SZ1031 and SZ1035 use standard terminal designation...

Page 3: ...sensor only Using remote room sensor with both discharge and outdoor air sensors SZ1031 and SZ1035 only KEYPAD ACCESS The dipswitches in the thermostat cover shown above must be set in order to lock...

Page 4: ...aud Rate Screen If using a PC to do programming all controllers on a network must be set to the same baud rate Choose between 2 4K 4 8K 9 6K and 19 2K Display Type Screen Choose between FAHRENHEIT and...

Page 5: ...4TH STAGE AS COOL 25 program setup ENABLE THIRD STAGE AS DISABLE 26 program setup HEAT STAGE 1 OFFSET 0F 27 program setup OCCUPIED COOL SETPOINT B 75F 16 program setup OCCUPIED COOL SETPOINT C 75F 17...

Page 6: ...etup ENABLE OUTDOOR AIR FUNCT YES 44 DISCHARGE AIR LOW LIMIT 45F ENABLE DISCHARGE AIR FUNCT YES program setup 41 program setup TIMECLOCK OUTPUT OCCUPIED CLOSED program setup 40 DISCHARGE AIR HIGH LIMI...

Page 7: ...CONDS DI3 USED FOR FILTER SERVICE program setup 50 program setup SET DI2 SETPOINT SHIFT 00F program setup 49 ENABLE SMART RECOVERY NO 52 program setup 51 program setup SET ACCESS CODE 248 55 MON 11 19...

Page 8: ...ed Times Screen Set hours and minutes of start and end times for up to two occupied periods Schedule Announcement Screen Announces the next screen Copy Schedule Screen Indicate whether or not to use t...

Page 9: ...such as with a switch or wind up timer If each occupancy period is about the same theaters meetings another option is to set the DI3 to external override and use the timed override button to put the...

Page 10: ...ment to the building load The offset value is the amount away from the setpoint a stage will turn off By assign ing a stage a value other than zero you anticipate that the residual heat or cooling in...

Page 11: ...35 also have a P I option Without enabling this option stages turn on and off based on temperature vs setpoint alone as described above By enabling this option you allow a time factor to be added This...

Page 12: ...support you may be able to use the on board adjustment pots Refer to the Thermostat Sensor Calibration Tech Bulletin 1005 for details setpoint adjustment limits Change this to 20 F 11 1 C Press the P...

Page 13: ...the override is active and if so how many minutes remain ing service status MON 11 19 01 12 00 AM 72F service status SERVICE STATUS OK 1 service status OUTDOOR AIR TEMP 75F 3 service status DISCHARGE...

Page 14: ...allow the occupant to change the system mode is allowed by factory default To lock out access to system switching see programming step 5 SETTING CLOCK SCHEDULE The ability to set the clock and schedul...

Reviews: