background image

 

14 

11/2012 

TCS TürControlSysteme AG  

  TCS Hotline:  +49 (0) 41 94 / 98 81 188

 

Subject to technical changes. 

FAX: +49 (0) 41 94 / 98 81 29  

  Mail: hotline@tcsag.de

 

PI_FBI4500-0100.doc                    2A 

Cleaning 

 

!

 

Avoid water from entering the device! 
Do not use any abrasive detergents! 

 

Clean the device with a dry or slightly wet cloth. 
Remove stronger stains with a mild household cleaner. 

 
 

Conformity  

 

The declarations of conformity are available under www.tcsag.de, Downloads, trade 
information. 

 
 

Information on disposal  

 

The adjoining symbol shows, that the device has to be disposed separately from 
domestic waste. The materials used are recyclable. Please do help protecting our 
environment and dispose the device via a collection point for electronic scrap. 
 

 

 
Dispose the parts of the packaging in collecting tanks for cardboard and paper 
resp. plastics. 

 
 

Warranty  

 

We offer a 

simplified processing

 in case of warranty for electricians. 

  Please note our 

conditions of sale and delivery

, download from www.tcsag.de, 

Downloads, trade information. 

  Please contact the

 TCS HOTLINE

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for FBI4500-0100

Page 1: ...S TürControlSysteme AG TCS Hotline 49 0 41 94 98 81 188 Subject to technical changes FAX 0 41 94 98 81 29 Mail hotline tcsag de PI_FBI4500 0100 doc 2A Product information PTZ camera interface FBI4500 0100 ...

Page 2: ...nnect the lines 7 Connection lines 7 5 wire special operation 8 Connect the camera 8 Voltage supply connection 8 Note for the connection of more than one interface 8 Setup the PTZ camera interface as end device 8 Wiring diagram TCS BUS system 9 Connection diagram 9 Commissioning 10 Commissioning the system 10 Storage in case of a voltage breakdown 10 Configuration 10 Presettings ex works 10 Config...

Page 3: ...rements according to DIN VDE 0100 must be observed When installing TCS BUS systems the general safety regulations for telecommunication systems according to VDE 0800 must be observed Inter alia separated conduit of heavy current and low current lines minimum distance of 10 cm in case of a common conduit use of separators between heavy and low current lines within shared cable ducts use of standard...

Page 4: ... be configured in the PTZ camera interface via the configuration software con figo as of version 1 7 x By specific actions at the TCS BUS door call control function the positions can be controlled On Screen Display OSD Dropdown menu which is displayed on the screen and can be activated by pressing the menu or image button of the device Intended use The PTZ camera interface FBI4500 0100 is a device...

Page 5: ...D Pelco P and Samsung Functions at the TCS BUS By navigating with the control keys resp Navigation buttons LEFT RIGHT UP DOWN at the indoor station a specific section of the image can be selected via a PTZ camera With the protocol topstitch or with the control function preferred positions can be controlled The configuration software configoTM supports the devices as of version 1 7 x Indication and...

Page 6: ... 130 x D 35 Weight 305 g Degree of protection IP65 Acceptable ambient temperature 20 C to 50 C Input current I a 0 4 mA Input current I P 25 mA stand by Max input current I Pmax 40 mA Video signal input 75 Ohm asymmetric 1 Vss FBAS Output level 2 wire video signal 3 dB to 9 dB manually adjustable 6 wire technique necessary Connection terminal TCS BUS Jumper 4 x Cover screws IP65 Housing with trans...

Page 7: ...ng Do not use the lower cover as drilling template as it may cause damage to the de vice Drill the marked holes and insert dowels into the wall if necessary Screw the housing firmly to the wall Guide the connection lines through the cable gland M12 screws Close the housing only after the installation and configuration Connect the lines Connection lines The connection of the connection line is atta...

Page 8: ...he camera Please observe the documentation of the manufacturer Voltage supply connection The voltage supply of the PTZ camera is not realised via the PTZ camera interface and not via the TCS BUS The PTZ camera is to supply separately with a power supply unit which is suitable for the camera To connect the special voltage supply the terminals K Power Kamera can be used in the FBI4500 ATTENTION The ...

Page 9: ...1 94 98 81 188 Subject to technical changes FAX 49 0 41 94 98 81 29 Mail hotline tcsag de PI_FBI4500 0100 doc 2A Wiring diagram TCS BUS system Connection diagram Place matching resistor at the last video indoor station Floor push button Floor push button ...

Page 10: ...eakdown Configuration Presettings ex works The device is equipped with an EEPROM which stores the following device settings ex works AS address camera 1 0 Control function for moving to prepositions 239 Second AS address for moving to preposition 2 camera 2 deactivated Automatic Stop protocol deactivated Camera address 1 Type of PTZ protocol to control the camera Pelco D Baud rate 2400 Bd Configur...

Page 11: ...tons of this indoor station you can move the PTZ camera into the required direction and the required zoom as far as possible or move the camera directly via configo To store the preposition in the PTZ camera press the button Store preset x Delete prepositions Start the configuration software configo Open the device FBI4500 within the configo To delete the preposition in the PTZ camera press the bu...

Page 12: ...Ω table 1 If the loop resistance exceeds 8 Ω use multiple wiring of the strands double drilled lines Optional strand or star shaped wiring Do not use more than 20 video indoor stations per strand For systems with more video indoor stations use video distributors FVY1200 FVY1400 Up to 64 front door stations 16 of them video front door stations and an unlimited number of indoor stations can be conne...

Page 13: ... Ohm away from the power supply and control unit VS Rule Switch off the 230 V 50 Hz of the VS Install a b short circuit at the VS All other devices do not disturb the measurement and can stay connected Measure the loop resistance at the strand at a b of the last IS or AS 8 Ohm max 65 m distance AS VS on 0 6 mm diameter max 115 m distance AS VS on 0 8 mm diameter AS Front door station VS Power supp...

Page 14: ...der www tcsag de Downloads trade information Information on disposal The adjoining symbol shows that the device has to be disposed separately from domestic waste The materials used are recyclable Please do help protecting our environment and dispose the device via a collection point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Wa...

Page 15: ...11 2012 15 TCS TürControlSysteme AG TCS Hotline 49 0 41 94 98 81 188 Subject to technical changes FAX 49 0 41 94 98 81 29 Mail hotline tcsag de PI_FBI4500 0100 doc 2A Notes ...

Page 16: ...es FAX 49 0 41 94 98 81 29 Mail hotline tcsag de PI_FBI4500 0100 doc 2A Service Please send your questions and inquiries to TCS HOTLINE 0 41 94 98 81 188 Head quarters TCS TürControlSysteme AG Geschwister Scholl Str 7 D 39307 Genthin Phone 49 0 39 33 87 99 10 FAX 49 0 39 33 87 99 11 www tcsag de ...

Reviews: