4
03/2013
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de
Subject to technical changes.
PI_FBI6110-uk 2 A
Technical data
supply voltage:
+26 V
±
8 % (power supply and control unit)
housing:
DIN-rail housing 6 SU for DIN-rail mounting
DIN EN 50022
weight
180 g
acceptable ambient temperature:
0 °C ... +40 °C
input current:
I(a) = 0.2 mA, I(P) = 110
mA
max. input current:
I(Pmax) = 135 mA
input impedance:
100 Ohm balanced
6-wire technique necessary!
Indication and operation elements
Term
Function
LED, green:
indication for operational
readiness
ON
: device is ready for operation
blinks
: during start and update procedure
LED, yellow:
error indication network
and SD card
flashes
: error in the network connection
or SD card is missing or defect
LED, red:
error indication TCS:BUS
flashes
: error in the connection to the TCS:BUS
®
RJ45 socket LAN 1
RJ45 socket LAN 2
each with LED, yellow
and LED, green
connection to the network
connection to the SIP-Gateway (if used)
LED, yellow: indicates data current
LED, green:
ON
, if the FBI6110 is connected to the
network resp. with the SIP-Gateway
push button reset
push button WE
to reset the FBI6110
to reload the factory setting of the FBI6110