6
03/2013
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de
Subject to technical changes.
PI_FBI6110-uk 2 A
error indication, optical (LED)
integrated two-wire video receiver for direct connection to TCS video systems
RJ45 socket for connection to the network (10/100 Base-TX)
RJ45 socket to connect a SIP-Gateway via an integrated switch
browser-based possibilty to send short messages to video indoor stations (ecoos
™
IVW221x, sky
™
IVW2221 or skyline
™
IVW3012).
Connect the lines
Note
!
Use a small screwdriver to connect lines and to avoid damaging the device.
Connection lines to the TCS system
acceptable cross-section (diameter)
0.08 … 0.82 mm
2
(Ø
0.32 … 1.0 mm)
max. number of wires per terminal contact
each 2 x Ø 0.8 mm or 3 x Ø 0.6 mm
Connect the device
Connect the device according to the wiring diagram.
Establish a connection between the socket LAN1 at the Video Streamer and your net-
work with a standard network cable.