Commissioning
!
First install the system completely, than connect it to the mains voltage!
V1 and V2 must not be connected with the P-, a- or b-wire.
When connecting the video wires V1 (+) and V2 (
−) the polarity must be observed. If
you see a distorted picture after the commissioning, switch off the device and ex-
change the wires for the video signal.
Ensure that the SD card is plugged accordingly to the marking on the type label in the
SD slot. The SD card is necessary for the storage of all configuration data and images.
The card must always be in the device.
!
For a safe functionality, only the enclosed SD card is to be used.
The SD card can be ordered as spare part directly at TCS (see
Switch on the mains voltage, the Video Streamer starts automatically. The LED indica-
tion (green) blinks for around 10 seconds and shines. The device is now ready for oper-
ation.
Error detection and indication
Errors when connecting the cables are signaled by flashing of the LED indication (red or
yellow). The optical error indication stays active until the error is corrected.
error causes
indication
error mode
our solution
a- and P-wire are mixed or
short-circuited
LED, flashes red
Exchange a- and P-wire or correct short-circuit,
LED expices.
a-wire not connected or not
supplied
Connect the a-wire or establish power supply, LED
expices.
error to the network connec-
tion or SD card is missing
LED, flashes yellow
Check the connection to the network, the SD card
is plugged in and whether the PC is operating.
Decommissioning
For certain activities on the system such as maintenance, the Video Streamer must be
removed from operation:
Switch off the power supply of the system.