background image

 

14 

(De-)Activate the DHCP client 

 

 

Es works the FBI6119-0400 is delivered with deactivated 
DHCP client. IP address ex works: 192.168.178.202 (ill. 10). 

 

 

Start the configo software

TM

 on your PC. 

 

Set resp. remove the checkmark from the box (De-)Activate 
DHCP.  

 

Update the EEPROM of the FBI6119-0400. 

 

      For further information on configo

TM

 refer to help function of 

the program.  

 

 

 

If the DHCP client is deactivated, you have to assign a 
valid IP address for the FBI6119-0400 manually.  

 

For further information refer to manual FBI6119-0400 or 
consult your network administrator. All manuals are 
available in the download area at www.tcsag.de . 

 

 

 

Fig. 10: DHCP client is activated  

 

 

Fig. 11: DHCP client is deactivated   

 

Change password for user and/or admin

 

 

 

Click e.g. the option 

Password "User“

  A new window will open (ill. 

13). 

 

Enter your old password into the text field 

Old password 

.

 

 

Enter your new password into the text field 

New password 

.

 

 

Repeat your entry in the text field 

Repeat new password

.

 

 

Click 

OK

.

 

 

Update the EEPROM of the FBI6119-0400. 

 

      For further information on configo

TM

 refer to help function of 

the program.  

 
 

 

 

Fig. 12: Changing the password  

 

 

Ill. 13: Create new password   

 
 
 
 
 

Summary of Contents for FBI6119-0400

Page 1: ...Product information IP audio video gateway BASIC FBI6119 0400 for 10 call destinations as of software version 02 A...

Page 2: ...ratingelements 6 Technicaldata 7 Mountingandinstallation 8 DIN railmounting 8 DismantlingfromtheDIN rail 8 Connecting the lines 9 Connectinglines 9 Connectingthelines 9 examplecircuitwith WLANhome net...

Page 3: ...re available in the download area at www tcsag de Usedsymbolsandwarningnotices Symbol signal word Explanation DANGER The signalworddescribes anendangeringwith ahighlevelofrisk Failure toobserve this w...

Page 4: ...ines minimum distance of 10 cm in case of a common cable routing use of separators between high and low voltage lines within shared cable ducts use of standard telecommunication lines e g J Y St Y wit...

Page 5: ...parallel calls per call destination can be configured specific connection establishment to a SIP call destination due to control function at TCS BUS device up to 10 TCS BUS call destinations can be ca...

Page 6: ...iness Indicationandoperatingelements LEDgreen OFF ON BLINKS slowly 1 Hz BLINKS fast 4 Hz deviceisoutofservice operational readiness thestart process oftheFBI6119 0400 is finished WELbutton ispressed 0...

Page 7: ...10 in case of door calls 200 internal call via control function if supported by the in door station TCS BUScalldestinations 10 integratedSIPserver up to 10 entries other functions Image buffer creatin...

Page 8: ...19 0400 on the DIN rail 1 Snap in the FBI6119 0400 with slight pressure 2 Check if the locking mechanism is securely engaged ill 2 Fig 1 DIN rail mounting Fig 2 Engaging Dismantling from the DIN rail...

Page 9: ...same material and with the same diameter within one terminal contact network connection patch cable RJ45 CAT 5e FTP 8 pin Connecting the lines Strip the lines Connect the lines a b P M V1 and V2 accor...

Page 10: ...10 examplecircuitwithWLANhomenetwork Fig 6 Example circuit...

Page 11: ...r your device Detailed information on our terms of service for TCS IP enabled systems you ll find at http www tcsag de fileadmin user_upload TCS_DE Metanavigation Service_Support Servicebedingun gen I...

Page 12: ...ork is very complex and requires appropriate background knowledge because of many inter connected parameter and settings Please contact your network administrator static and dynamic IP addresses and D...

Page 13: ...which IP address the front door station can be reached The smartphone can have a dynamic IP address because the device itself provides no service For further information on installation refer to manua...

Page 14: ...rther information refer to manual FBI6119 0400 or consult your network administrator All manuals are available in the download area at www tcsag de Fig 10 DHCP client is activated Fig 11 DHCP client i...

Page 15: ...ts Remove strongerstains with a pH neutral household cleaner Conformity Declarations of conformity are available for download under www tcsag de Information on disposal Dispose the device separately f...

Page 16: ...rters TCST rControlSystemeAG Geschwister Scholl Str 7 39307Genthin Germany FON 49 0 3933 8799 10 FAX 49 0 3933 879911 www tcsag de Subjecttotechnicalchanges TCS Hotline Germany FON 494194 9881188 Fax...

Reviews: