background image

 

 

 

Technical data 

call signalling 

 

SIP compatible 

audio  

 

half-duplex (integrated echo suppressor) 

 

codecs: G.711 (A/μ), G.726 832 kbps), GSM 6.10, iLBC, Speex 

 

up to 5 clients can be called parallel 

video encoding 

 

 

encodes video from TCS:BUS to IP 

 

JPEG single image, MJPEG and H.264 streaming 

 

QVGA and VGA, up to 25 fps (adjustable) 

 

up to 10 simultaneous streams 

 

live stream via web interface 

sending messages to TCS:BUS 

 

 

via web interface 

control functions 

 

 

door release and switching lights via SIP DTMF 

 

up to 10 user-specific control functions can be configured (can 
be triggered via web interface) 

SIP call destinations 

 

 

10 (in case of door calls) 

 

200 (internal call via control function, if supported by the in-
door station) 

TCS:BUS call destinations 

 

 

10 

integrated SIP server 

 

 

up to 10 entries 

other functions 

 

 

Image buffer 

 

creating XML file for notify of compatible VoIP telephones 
without H.264 (e.g. Snom, Gigaset, Auerswald) 

 

visual status and error indication via LEDs 

 

IP address via configo

TM

 adjustable 

 

multi-lingual web interface 

interfaces  

 

SD card (max. 2 GB), RJ45 connection, 6-wire TCS:BUS via 
screw terminals 

operating voltage 

 

V

min

 15 V DC – V

max

 28 V DC 

input current in resting position 

 

I(a) = 0.1 mA, I(P) = 200 mA 

max. input current: 

 

I(Pmax) = 250 mA 

degree of protection 

 

IP20 

housing  

plastics 

 

 

DIN-rail housing 6 SU according to DIN 43880 for DIN-rail mounting 
(DIN EN 60715) 

dimensions (in mm) 

 

H 90 x W 104 x D 70  

acceptable ambient temperature 

 

0 °C … + 40 °C  

 

 
 
 
 
 
 

Summary of Contents for FBI6119-0400

Page 1: ...Product information IP audio video gateway BASIC FBI6119 0400 for 10 call destinations as of software version 02 A...

Page 2: ...ratingelements 6 Technicaldata 7 Mountingandinstallation 8 DIN railmounting 8 DismantlingfromtheDIN rail 8 Connecting the lines 9 Connectinglines 9 Connectingthelines 9 examplecircuitwith WLANhome net...

Page 3: ...re available in the download area at www tcsag de Usedsymbolsandwarningnotices Symbol signal word Explanation DANGER The signalworddescribes anendangeringwith ahighlevelofrisk Failure toobserve this w...

Page 4: ...ines minimum distance of 10 cm in case of a common cable routing use of separators between high and low voltage lines within shared cable ducts use of standard telecommunication lines e g J Y St Y wit...

Page 5: ...parallel calls per call destination can be configured specific connection establishment to a SIP call destination due to control function at TCS BUS device up to 10 TCS BUS call destinations can be ca...

Page 6: ...iness Indicationandoperatingelements LEDgreen OFF ON BLINKS slowly 1 Hz BLINKS fast 4 Hz deviceisoutofservice operational readiness thestart process oftheFBI6119 0400 is finished WELbutton ispressed 0...

Page 7: ...10 in case of door calls 200 internal call via control function if supported by the in door station TCS BUScalldestinations 10 integratedSIPserver up to 10 entries other functions Image buffer creatin...

Page 8: ...19 0400 on the DIN rail 1 Snap in the FBI6119 0400 with slight pressure 2 Check if the locking mechanism is securely engaged ill 2 Fig 1 DIN rail mounting Fig 2 Engaging Dismantling from the DIN rail...

Page 9: ...same material and with the same diameter within one terminal contact network connection patch cable RJ45 CAT 5e FTP 8 pin Connecting the lines Strip the lines Connect the lines a b P M V1 and V2 accor...

Page 10: ...10 examplecircuitwithWLANhomenetwork Fig 6 Example circuit...

Page 11: ...r your device Detailed information on our terms of service for TCS IP enabled systems you ll find at http www tcsag de fileadmin user_upload TCS_DE Metanavigation Service_Support Servicebedingun gen I...

Page 12: ...ork is very complex and requires appropriate background knowledge because of many inter connected parameter and settings Please contact your network administrator static and dynamic IP addresses and D...

Page 13: ...which IP address the front door station can be reached The smartphone can have a dynamic IP address because the device itself provides no service For further information on installation refer to manua...

Page 14: ...rther information refer to manual FBI6119 0400 or consult your network administrator All manuals are available in the download area at www tcsag de Fig 10 DHCP client is activated Fig 11 DHCP client i...

Page 15: ...ts Remove strongerstains with a pH neutral household cleaner Conformity Declarations of conformity are available for download under www tcsag de Information on disposal Dispose the device separately f...

Page 16: ...rters TCST rControlSystemeAG Geschwister Scholl Str 7 39307Genthin Germany FON 49 0 3933 8799 10 FAX 49 0 3933 879911 www tcsag de Subjecttotechnicalchanges TCS Hotline Germany FON 494194 9881188 Fax...