background image

HE360A POWERED FLOW-THROUGH HUMIDIFIER

68-0273

6

Every 1 To 3 Months 

(Depending on Water Quality)

1.

Disconnect the power and turn off the humidifier water 

supply.

2.

Remove the humidifier cover. See Fig. 6.

Fig. 6. Location of humidifier parts.

3.

Remove humidifier pad assembly from the humidifier by 

grasping the tray and pulling it toward you.

4.

Pull one side of the humidifier pad assembly frame 

toward you and remove the tray from the frame.

5.

Gently pinch the water nozzle catches inward until the 

water nozzle can be lifted off the tray.

6.

Slide the humidifier pad out of the frame.

7.

Carefully scrape any mineral deposits from the tray and 

frame. Be sure the frame drain hole has no blockage.

8.

Check the humidifier pad and if excessive mineral 

deposits are present, replace with a new pad.

9.

Disconnect the drain hose from the drain fitting on the 

bottom of the humidifier housing.

10.

Clean the drain fitting, if necessary.

11.

Bend the drain hose to loosen any mineral deposits.

12.

Flush the drain hose with pressurized water (a running 

tap) to clean the hose.

13.

Reattach the drain hose to the drain fitting.

14.

Slide the humidifier pad back into the frame.

IMPORTANT

For proper performance, ensure the marked end of 

the humidifier pad is upward facing.

15.

Reattach the tray to the frame.

16.

Snap the water nozzle back on the tray.

17.

Place the humidifier pad assembly in the humidifier 

housing and press until the assembly is seated.

18.

Be sure the water feed tube is placed in the guide slots 

of the humidifier housing.

19.

Replace the humidifier cover.

20.

Verify the humidifier operation by following the steps in 

the Checkout Procedure section.

End of Humidification Season

The humidifier needs to be cleaned and shut off at the end of 

the heating season. Follow steps 1 through 19 from the Every 

1 To 3 Months section.

IMPORTANT

Be sure the humidifier power is off.

Beginning of Humidification Season

Refer to the Checkout Procedure section for complete 

humidifier startup instructions.

Vacation

Turn off the humidifier water supply and the humidity control 

while on vacation. When you return, turn on the humidifier 

water supply and reset the humidity control to restart the 

humidifier.

CHECKOUT PROCEDURE

After winter startup or servicing, use the following steps to 

check the humidifier operation.

1.

Turn on the humidifier power and water supply.

2.

Turn humidity control to its highest setting and set the 

thermostat to 10°F (12°C) above the room temperature.

3.

Observe that water is flowing out of the drain hose.

NOTE: The furnace blower must be operating for the 

humidifier to work.

4.

Reset thermostat and humidity control to a comfortable 

setting for automatic operation.

M20811

COVER 
ASSEMBLY

HUMIDIFIER 
PAD ASSEMBLY

FEED TUBE NOZZLE

WATER 
DISTRIBUTION TRAY

HUMIDIFIER
HOUSING

THUMB 
SCREW

Summary of Contents for HE360A

Page 1: ...ibution tray for optimal efficiency and water usage Proven technology used for high performance humidification Narrower footprint than popular compatible model while maintaining a common humidifier pa...

Page 2: ...ged Total Comfort System Model Available HE360A Includes humidifier humidifier pad mounting template self piercing saddle valve and H908 Convertible Humidity Control Capacity At 120 F 49 C plenum temp...

Page 3: ...in wc and water pressure is no greater than 125 psi Location and Mounting IMPORTANT Mount the humidifier at least 3 in 76 mm above the furnace jacket to allow adequate space for the drain line Check...

Page 4: ...es and regulations H8908 Humidistat Wiring Connections IMPORTANT Select models of fan centers include humidifier taps so the current sensing relay or sail switch is not needed If not using a current s...

Page 5: ...should reduce the accumulation of moisture and ice on the windows and in other areas of the house Some indoor activities such as cooking showering and clothes drying can cause excessive levels of hum...

Page 6: ...water nozzle back on the tray 17 Place the humidifier pad assembly in the humidifier housing and press until the assembly is seated 18 Be sure the water feed tube is placed in the guide slots of the...

Page 7: ...y Condensation on walls Turn off humidity control and water until condensation is completely evaporated Heavy condensation on windows Turn down humidity control low enough to eliminate condensation ca...

Page 8: ...ic Drive Golden Valley MN 55422 Scarboroug Ontario MiV 4V9 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers HE360A POWERED FLOW THROUGH HUMIDIFIER Fig 7 Exploded vi...