Operation Instructions: TCS Duplicating Unit Model TC105

www.tcsdentalinc.com / 866-426-2970

I112012 Rev D

Effective Date: 11/12/19

Before Plugging in Unit

Sec. I Filling the Unit with Antifreeze

1.  Disconnect Mixer Power Plug from the back of the unit and remove 

lid (with mixer) by lifting straight up by the 2 handles. Set lid carefully 

on its side. 

FIG 1

2.  DO NOT lift lid from Mixer Motor.

 

FIG 1a & 1b

3.  Place a funnel into Antifreeze Intake Pipe located at the back of unit. 

Pour in 100% pure antifreeze, the unit will take almost the entire 

gallon of antifreeze that was included with the unit. Check antifreeze 

indicator on the side of unit to ensure that it is half full. 

FIG 2

IMPORTANT: 

100% Pure Antifreeze must be used. Do not 

substitute antifreeze. In case too much antifreeze is poured in, it 

will overflow from the Intake Pipe.

Note:

 

Always maintain level of antifreeze at half full according to 

Antifreeze Indicator. 

FIG 2

Depending on use and other variables, more antifreeze will have to be 

added a few times per year. 

4.  With a damp cloth clean inside of unit and remove any antifreeze 

fluid that may have poured in.  

Manufac

tured in the U

.S.A.

L111412 RE

V NE

W

ANTIFREEZE

Antifreeze Indicator 

should be half full.

Manufac

tured in the U

.S.A.

L111412 RE

V NE

W

Manufac

tured in the U

.S.A.

L111412 RE

V N

EW

Manufac

tured in the U

.S.A.

L111412 RE

V NE

W

FIG 1

FIG 1a

FIG 1b

FIG 2

General Safety Hazard:

 Refer to the instructions for details on the specific hazard.

Caution:

 Hot surface warning

Caution:

 Electrical shock hazard

Technical Symbol:

 All operations marked with this symbol are to be performed by qualified maintenance 

personnel only.

Your safety and the safety of others are important. We have provided important safety messages in this manual. Please read these messages 

carefully. A safety message alerts you to potential hazards that could hurt you or others. Each safety message is associated with a safety alert 

symbol. The definition of these symbols are described below:

2.  

Unpacking and Safety

3.  

First Time Use

Ventilation Clearance: 

AREA

MINIMUM REQUIRED CLEARANCE

Back of the instrument

10 cm / 4 inches

Sides of the instrument

20 cm / 8 inches

Above

30 cm / 12 inches

Below

N/A

Warning: DO NOT PLUG IN

 

unit until filled with 100% pure antifreeze.

Caution:

 

High voltages are present. The line power connections must have a functioning ground connection 

and over voltage protection in the form of a fuse or circuit breaker. 

** DO NOT DEFEAT THE GROUND WIRE ON POWER PLUG

** TURN OFF INJECTOR BEFORE DISCONNECTION OR CONNECTING ELECTRICAL PLUGS