TCF EVO Line and TCF X Line
Faults, messages, causes and remedies
Faults, messages, causes and remedies
The screwdriver
does not start.
Control cable on
screwdriver loose
Plug on screwdriver
without contact
Clean plug contacts and push
control cable onto plug contacts.
Check control cable for
continuity.
Have screwdriver repaired by
Technik Center Schraubsysteme
GmbH.
In the mouthpiece
come
no screws on.
The sorting pot of the
Feed module is empty.
Observe the minimum bending
radius (=150 mm) of the cable
conduit package.
Pressure for the supply
air shock
set too low
Compressed air at the
maintenance unit
set too low.
Set air pressure to 5 - 6.5 bar
flow pressure
Check compressed air supply
Switch-off torque was
not reached (with
valve query)
Check air pressure at the feeder
module
Wrong screw type in
the sorting pot of the
feeder module
Screws shoot
through the
mouthpiece
Wrong mouthpiece
mounted on the
screwdriver.
Summary of Contents for TCF EVO Line
Page 9: ...TCF EVO Line and TCF X Line System overview 9 Abb 2 Structure of the system 4 15 17 16 10 11 ...
Page 102: ...TCF EVO Line and TCF X Line Connection of USB stick to the display 102 ...
Page 119: ...TCF EVO Line and TCF X Line Spare and wear parts 119 14 6Feeding module ...
Page 120: ...TCF EVO Line and TCF X Line Spare and wear parts 120 14 7Guide rail ...
Page 122: ...TCF EVO Line and TCF X Line Spare and wear parts 122 14 8Separation chopper ...
Page 125: ...TCF EVO Line and TCF X Line Spare and wear parts 125 14 9Pneumatics ...
Page 126: ...TCF EVO Line and TCF X Line Spare and wear parts 126 14 10 Sorting pot ...
Page 131: ...TCF EVO Line and TCF X Line Spare and wear parts 131 14 14 Module delivery unit ...
Page 133: ...Original instruction manual ...