TCF EVO Line and TCF X Line
Functions of the modules and settings
completely extended after the reloading process (accessories: magnet bit,
vacuum). If the option blade extended is selected, the drive is started briefly
during extension so that the blade can reliably find the engagement feature
of the screw.
Here it is possible to define screwdriver-dependent settings of the TC-HF
Reloading with blade centre position
If the option is set to "ACTIVE", the
blade is moved to the middle position
Reload with blade Extended active
If the option is set to "ACTIVE", the
Blade fully extended AST Delay [sec].
If this value is greater than 0 and the
option "Reload with blade extended
active" is active, the blade extension
is delayed by the defined time before
TC-HF V1 Delay reloading after
Start button off (only for test purposes
value must always be 0 for a TC-HF
V2 screwdriver.
In order to be able to prepare a TC
HF V1 screwdriver in exceptional
Summary of Contents for TCF EVO Line
Page 9: ...TCF EVO Line and TCF X Line System overview 9 Abb 2 Structure of the system 4 15 17 16 10 11 ...
Page 102: ...TCF EVO Line and TCF X Line Connection of USB stick to the display 102 ...
Page 119: ...TCF EVO Line and TCF X Line Spare and wear parts 119 14 6Feeding module ...
Page 120: ...TCF EVO Line and TCF X Line Spare and wear parts 120 14 7Guide rail ...
Page 122: ...TCF EVO Line and TCF X Line Spare and wear parts 122 14 8Separation chopper ...
Page 125: ...TCF EVO Line and TCF X Line Spare and wear parts 125 14 9Pneumatics ...
Page 126: ...TCF EVO Line and TCF X Line Spare and wear parts 126 14 10 Sorting pot ...
Page 131: ...TCF EVO Line and TCF X Line Spare and wear parts 131 14 14 Module delivery unit ...
Page 133: ...Original instruction manual ...