background image

REV 2.3 

 

     © 2012 TCW Technologies, LLC. 

9

6)  Turn off the Back-up Master Switch and confirm that the engine turns off. 

 

7)  IF all these tests pass, the IBBS system is functioning properly, record the results in 
the aircraft log book.    
 
8)  IF any of these tests fail, the IBBS system is not functioning properly and corrective 

action must take place. If the IBBS no longer meets the endurance testing 
requirement, the back-up battery may need replacement. 

 
9) Return all pullable breakers to the normal ON position and ensure aircraft engine is 
properly returned to the off position by following normal run and shut-down procedures. 

 

 
10) After completing these tests, recharge the IBBS product by operating the system 
normally for up to two hours. This may be done by operating the aircraft in conditions 
known to not require back-up power or by powering the aircraft system on a suitable 
ground power source as described in the section: Ground Base Recharging. 
 

 

 
 
 
For service or if you have questions, please contact us. 
 
 
 
610-928-3420 

www.tcwtech.com

 

email: support@tcwtech.com 
 

 

TCW Technologies, LLC.                   

 

 

 

2955 Main Road East   

 

 

 

 

 

Emmaus, PA 18049 

 

 

 

 

 

 

Summary of Contents for IBBS-12v-2ah

Page 1: ...output power during normal and emergency operations The IBBS system also provides an output signal to communicate the operating state of the back up bus as well as the state of the battery The IBBS sy...

Page 2: ...lect an installation location that will comply with these requirements 4 Connect the aircraft wiring according to one of the wiring diagrams shown The IBBS must be powered through a properly sized cir...

Page 3: ...tem connections directly to aircraft battery must be utilized as shown 8 When using the IBBS product to provide back up power to an electronic ignition system CDI pullable circuit breakers must be use...

Page 4: ...on the input of the IBBS the info line may be read to determine the internal battery voltage A nominal battery with a full charge will read between 12 and 15 volts When the IBBS is on line providing b...

Page 5: ...harged battery the following average performance can be expected in terms of operating duration The operating duration is for output voltage down to 9 5 volts Nominal Current Draw Duration total conne...

Page 6: ...procedures Start up Procedure 1 Prior to turning on the Aircraft Master Switch turn ON the Back up Power master switch 2 Turn on any equipment that derives back up power from the IBBS product 3 Ensure...

Page 7: ...he Back up Power Master Switch 3 Turn on all equipment connected to and supplied with back up power from the IBBS product 4 Measure and record at least the following information The time until the fir...

Page 8: ...operation based on the use of only the electronic ignition module provided with back up battery power 3 PULL the 5 amp breaker feeding the Back up Master Switch confirm engine continues to run 4 PULL...

Page 9: ...ullable breakers to the normal ON position and ensure aircraft engine is properly returned to the off position by following normal run and shut down procedures 10 After completing these tests recharge...

Page 10: ...l high performance fast charger Surge Protection 16 volt active clamp 1500w 10 1000uS waveform Wiring CPC connector with Mil spec machined contacts Field replaceable inline fuse AGC 7 5 Enclosure Cast...

Page 11: ...rness PIN Description Wire Color optional harness 1 Main Aircraft Bus charge power Red 2 Aux Battery trickle charge Always ON Purple yellow 3 Aircraft ground Black 4 Back up power master switch White...

Page 12: ...g 20 awg www tcwtech com Emmaus PA USA MODEL IBBS 12V 2AH Input 10 15 volts DC Output 12 volts 3 amps Capacity 2 amp hours INTEGRATED Back up Battery SYSTEM Pin 1 Main Aircraft Bus Pin 2 Aux Battery t...

Page 13: ...hout back up power inputs Equipment without Back up Power Input 2 amps 10 amp Main Aircraft Bus Aux Battery trickle charge Back up Power Master cpc connector INFO Low active signal High battery voltag...

Page 14: ...x Battery trickle charge Back up Power Master cpc connector INFO Low active signal High battery voltage Back up power input 20 awg 22 awg 22 awg 20 awg 20 awg 22 awg 20 awg www tcwtech com Emmaus PA U...

Page 15: ...REV 2 3 2012 TCW Technologies LLC 15 Main Aircraft Bus 20 awg Shielded...

Page 16: ...REV 2 3 2012 TCW Technologies LLC 16...

Page 17: ...Emmaus PA or such place as TCW may designate freight prepaid PRODUCT IMPROVEMENTS TCW reserves the right to change or improve its products or any portions thereof without being obligated to provide su...

Reviews: