TDI-Dynaload Division
WCL488 Series Water Cooled Electronic Loads
Operation & Programming Manual
402828, Rev. B1
Page 85
V1 Constant Voltage Pulsing Base Level
Description
This command is used to set the base level when pulse loading in the
Constant Voltage mode.
NOTE:
When pulsing in constant voltage mode, higher voltage
corresponds to less drive. Therefore, V1 is a higher value than
V2.
Command Syntax
V1 <NR2>
Example
V1 75.0
This will set the base Constant Voltage level to 75.0 Volts.
Query Syntax
V1?
Returned Parameters TEXT ON: <NR2> volts
TEXT OFF: <NR2>