30
83488001 Revision N
circuitry will interrupt the power supply's operation causing it to turn OFF. For a full
explanation of each control and indicator refer to Section 5.
6.2.
Remote Operation (All models)
All 802 models are easily controlled through the 25 pin sub D-type remote interface
connector located on the rear panel. The minimum required signals for remote control
operation are; HV ON/OFF, Vprogram and GND. The remaining signals are provided for
status monitoring and fault diagnosis, or more sophisticated control methodologies. The
function each signal is shown in Table 6, with a schematic showing a suggested remote
interface circuit shown in Figure 12.
Pin
Signal Name
I/O
Description
1
Analog Out
O
0-10V (±1%) Analog of output voltage waveform. Impedance 1k
If the 5V option is
installed the voltage level is 0-5V.
3
Inhibit LED
O
Open collector through 100
. Low impedance when INHIBIT signal applied. See Note
1.
5
End of Charge
LED
O
Open collector through 100
. Low impedance when power supply reaches End of
Charge. See note 1.
7
Inhibit Input
I
5-15V Inhibits unit, open or ground allows operation. Input impedance >10k
Note use
either INHIBIT or INHIBIT, never both signals. Do not use the INHIBIT BNC as well as
the INHIBIT signal.
8
HV ON/OFF
I
15V=On, ground or open =Off. Also used to reset latching faults by cycling from On to
Off. Input impedance >1M
If the EN option is installed 15V=Off, Ground or open = On
9
Peak output volts
O
0-10V (±1%) Peak detector of output voltage waveform. Can be used to drive a meter
displaying peak charging voltage. Impedance 10k
. If the 5V option is installed the
voltage level is 0-5V.
10
HV ON LED
O
Open collector through 100
. Low impedance when HV output is enabled. See Note 1.
12
GND
Control circuit return. Also chassis/earth ground.
13
Charge current
O
Uncalibrated Analog of output current waveform. Impedance 10k
14
+15V
O
+15V through 100
16
Overtemp LED
O
Open collector through 100
. Low impedance when inverter over temperature
condition occurs. See Note 1.
17
Interlock LED
O
Open collector through 100
. Low impedance when external interlock circuit is open.
See Note 1.
18
Load fault LED
O
Open collector through 100
. Low impedance when load fault condition occurs. Load
fault is normally a non-latching fault and will self-reset after approximately 500ms,
unless caused by an output overvoltage where the supply will latch off. For models with
the LP option, an external RESET cycle is required to restart the unit. See Note 1.
19
Summary Fault
LED
O
Open collector through 100
. Low impedance indicated a summary fault condition.
Summary fault is a logical OR of Overvoltage, Overtemp, AC Line, and Open Interlock
conditions. See Note 1.
20
Inhibit Input
I
0V Inhibits unit, 15V or open allows operation. Input impedance >10 k
Note use
either INHIBIT or INHIBIT, never both signals. Do not use the INHIBIT BNC as well as
the INHIBIT signal.
22
Vprogram
I
0-10V = 0-100% of rated output voltage. Input impedance >1M
. If the 5V option is
installed the voltage level is 0-5V.
23
HV OFF LED
O
Open collector through 100
. Low impedance when HV output is off/disabled. See
Note 1.
24
GND
Control circuit return. Also chassis/earth ground.
25
+12V Unfiltered
O
+12V Raw, unfiltered
Summary of Contents for 802 Series
Page 2: ...PAGE LEFT INTENTIONALLY BLANK ...
Page 10: ...4 83488001 Revision N Notes ...
Page 34: ...28 83488001 Revision N Notes ...
Page 44: ...38 83488001 Revision N Notes ...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......