7
83488001 Revision N
1.5.
Continuous DC Operation
Although the 802 series has been designed for capacitor charging applications, they can
also be used as a continuous DC High Power Source for RF tubes such as klystrons,
TWTs, or other DC loads such as DC-DC converters. The DC option must be specified
when ordering, and the supply will be factory setup and tested with a continuous DC load.
When 802 supplies are operated in continuous DC applications it is often necessary to add
an external capacitor between the load and ground to improve the ripple performance of
the unit. Our online Application Note 505 describes operating capacitor charging supplies
in DC applications, and gives guidance in determining the size of any additional external
filter capacitance required. App Note 505 can be found at:
http://www.us.tdk-lambda.com/hp/pdfs/application%20notes/93008505rC.pdf
Consult the factory before connecting parallel units in continuous DC applications.
1.6.
Additional Features:
Internal contactor and fuses for AC disconnect and protection
Standard AC power and control connectors
Documentation Manual Including -
Installation, check out, suggested remote interfaces and control circuits
10 ft (3m). Output cable is standard, other lengths are optional.
1.7.
Safety Precautions
All 802 power supplies are designed to minimize the risk of fire or shock
hazard. This instrument received comprehensive mechanical and
electrical inspection prior to shipment. Nevertheless, certain safety
precautions must be observed. Only TECHNICALLY QUALIFIED
SERVICE PERSONNEL familiar with the principles of electrical safety
should operate this supply. The power supply SHOULD NOT BE
EXPOSED TO WATER OR MOISTURE OR DUSTY ENVIRONMENTS.
Electrical safety must be maintained at all times.
Lethal voltages are developed within the power supply's enclosure and
at the output cable. Therefore, the cover may not be removed by the
user (see Warranty in preamble section for variance). Also, the large
capacitors in the supply may store power even after the AC input line is
removed. ALLOW AT LEAST 40 SECONDS DISCHARGE TIME
between removing the AC input line and opening the cover. ALSO,
ALLOW AT LEAST 40 SECONDS between switching the AC power off
and switching it on again.
1.7.1.
This product is designed for Indoor use.
1.7.2.
This product is designed for pollution degree 2.
1.7.3.
This product is designed for Transient Overvoltage Category II
1.7.4.
Ensure all covers are in place and securely fastened before switching ON the AC
power.
1.7.5.
Proper grounding from the input AC power is required to reduce the risk of electric
shock. Ensure that the AC Protective Earth Ground connection has at least the same
gauge wire as the supply leads shown in Table 2.
Summary of Contents for 802 Series
Page 2: ...PAGE LEFT INTENTIONALLY BLANK ...
Page 10: ...4 83488001 Revision N Notes ...
Page 34: ...28 83488001 Revision N Notes ...
Page 44: ...38 83488001 Revision N Notes ...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......