20/22
TDK-Lambda
CUS600M
INSTRUCTION MANUAL
Allowable area touched by metal pieces are 9mm from each PCB conrners.
(2)
Conditions to meet Isolation and Withstanding Voltage standard.
Keep 5mm space from the surfaces and sides of PCB. Especially, 8mm space is necessary from the solder surface. If the space is not
enough, the specification of isolation or withstanding voltage will not be satisfied.
(3)
For Class I end equipment,
(Functional Earth) should be connected to the earth terminal of the equipment. Also the mounting hole
are should be connected to the Chassis by metal spacer. If not, the conducted noise, radiation noise and output noise may increase.
Please refer to below setup.