5/22
TDK-Lambda
CUS600M
INSTRUCTION MANUAL
1
.
Model name identification method
CUS 600M – 12 /
□
Option (*1)
(*1)
Blank : Standard type.
Rated Output Voltage / ADJ : Output voltage adjustable model.
Output Power (actual output / SF : Single fuse model.
power refer to the specification) / EF : End fan model.
Series Name. / C : Solder side coating
Note : For “/EF”model , please refer to instruction manual of CUS600M/EF.
For “/C” model, to improve resistance against humidity and dust environment, solder side of assembled PCB is coated. However,
complete effect is not guaranteed, because some areas on the board are not coated.
2
.
Terminal Explanation
L
N
INPUT
V+
V-
OUTPUT
1
2
3
4
5
6
7
8
9
10
CN1
CN51
CN61
11
12
COMPONENT SIDE
CN62
VR51
①
Mounting hole (hole diameter :
φ
3.5mm), This hole is not connected to functional earth of CN1. The mounting surface of
the spacer should be within Max 7mm.
②
L : Input terminal
φ
Live line (Fuse in line.).
③
N : Input terminal Neutral line (Fuse in line.).
④
: Functional earth terminal.
⑤
Mounting hole (hole diameter :
φ
3.5mm), This hole is connected to functional earth of CN1. The mounting surface of the
spacer should be within Max
φ
7mm.
⑥
Mounting hole (hole diameter :
φ
3.5mm)
.
For Class I end equipment, this hole should be connected to
○
5
to improve
EMC characteristics. For Class II end equipment, this hole can’t be connected to
○
5
.
⑦
V-: - Output Terminal.
⑧
V+: + Output Terminal.
⑨
VR51 : Output voltage adjustment trimmer only for /ADJ sub-model. The output voltage rises when the trimmer is turned
clockwise.
⑩
CN61 Terminal.
⑪
CN62 Terminal
.
⑫
Same as mounting hole
○
1 .