2. SPECIFICATIONS
2.1.
OUTPUT RATING
MODEL
GEN
8-400
10-330
15-220
20-165
30-110
40-85
60-55
80-42
100-33
150-22
300-11 600-5.5
1. Rated output Voltage (*1)
V
8
10
15
20
30
40
60
80
100
150
300
600
2. Rated output Current (*2)
A
400
330
220
165
110
85
55
42
33
22
11
5.5
3. Rated output Power
W
3200
3300
3300
3300
3300
3400
3300
3360
3300
3300
3300
3300
2.2.
INPUT CHARACTERISTICS
V
8
10
15
20
30
40
60
80
100
150
300
600
Single Phase models: 170-265V, 47~63Hz.
3-Phase, 200V models: 170~265V, 47~63Hz.
1. Input voltage/freq. (*3)
---
3-Phase, 400V models: 342~460V, 47~63Hz.
Single phase
A
24.0
24.0
24.0
24.0
23.0
24.0
23.0
23.5
23.0
23.0
23.0
23.0
3~Phase, 200V
A
14.5
14.5
14.5
14.5
14.0
14.5
13.6
14.0
13.7
13.7
13.8
13.9
2. Maximum input
current at 100% load
3~Phase, 400V
A
7.2
7.2
7.2
7.2
7.0
7.2
6.8
7.0
6.8
6.8
6.9
7.0
3. Power Factor (Type)
---
Single Phase models: 0.99@200Vac, rated output power. 3-Phase models: 0.95@200/380Vac, rated output
power.
4. Efficiency (*4)
%
82
83
83
83
86
86
88
88
88
87
87
87
Single Phase and 3-Phase 200V models: Less than 50A
5. Inrush current (*5)
--
3-Phase 400V models: Less than 20A
2.3.
CONSTANT VOLTAGE MODE
V
8
10
15
20
30
40
60
80
100
150
300
600
1. Max. line regulation (*6)
---
0.01% of rate output v2mV
2. Max. load regulation (*7)
---
0.015% of rated output v5mV
3. Ripple and noise p-p (20MHz) (*8)
mV
60
60
60
60
60
60
60
80
100
100
300
500
4. Ripple r.m.s 5Hz~1MHz
mV
8
8
8
8
8
8
8
25
25
25
100
120
5. Temp. coefficient
PPM/°C 100 PPM/°C @ Rated Current, following 30 minute warm up
6. Temperature Stability
---
0.05% of rate V
out
for 8hrs after 30 min warm-up. Constant line, load & temp.
7. Warm up drift
---
Less than 0.05% of rated output 2mV over 30 minutes following power on.
8. Rem. Sense compensation/wire
V
2
2
2
2
5
5
5
5
5
5
5
5
9. Up prog. Response time, 0~Vomax.(*9)
mS
80
150
200
250
Full load (*9)
mS
20
100
160
300
500
10. Down-prog.
response time
No load (*10)
mS
500
600
700
800
900
1000
1100
1200
1500
2000
3900
4000
11. Transient response time
mS
Time for output voltage to recover within 0.5% of its rated output for a load change 10-90% of rated output
current. Output set-point: 10-100%, Local sense.
Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
12. Hold-up time (Typ)
mS
10mSec for Single-Phase and 3-Phase 200V models, 6mSec for 3-Phase 400V models. Rated output power.
2.4.
CONSTANT CURRENT MODE
V
8
10
15
20
30
40
60
80
100
150
300
600
1. Max. line regulation (*6)
---
0.01% of rate output c2mA
2. Max. load regulation (*11)
---
0.02% of rated output c5mA
3. Load regulation thermal drift
---
Less than 0.1% of the rated output current over 30 minutes following load change
4. Ripple r.m.s 5Hz~1MHz (*12)
mA
1300
1200
880
660
300
200
100
80
70
60
20
10
5. Temp. coefficient
PPM/°C 100 PPM/°C from rated output voltage, following 30 minutes warm-up
6. Temperature Stability
---
0.05% of rated I
out
for 8hrs after 30 min warm-up. Constant line, load & temp.
---
8-20V model: Less than +/-0.5% of rated output current over 30 minutes following power on.
7. Warm up drift
30V-600V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
2.5.
ANALOG PROGRAMMING AND MONITORING
1. V
out
voltage programming
---
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity. +/-0.5% of rated V
out
.
2. I
out
voltage programming (*13)
---
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity. +/-1% of rated V
out
.
3. V
out
resistor programming
---
0~100%, 0~5V/10Kohm full scale, user selectable, accuracy and linearity. +/-1% of rated V
out
.
4. I
out
resistor programming (*13)
---
0~100%, 0~5V/10Kohm full scale, user selectable, accuracy and linearity. +/-1% of rated V
out
.
5. On/off control
---
By elect. Voltage: 0~0.6V/2~15V, or dry contact (Open/Short) user selectable logic.
6. Output current monitor (*13)
---
0~5V or 0~10V, accuracy: +/-1%, user selectable
7. Output voltage monitor
---
0~5V or 0~10V, accuracy: +/-1%, user selectable
8. Power supply OK signal
---
4~5V-OK, 0V-Fail. 500ohm series resistance
9. Parallel operation
---
Possible, up to 4 identical units in master/slave mode with two wire current balance connection
10. Series operation
---
Possible, up to 2 identical units (with external diodes).
11. CV/CC indicator
---
Open collector. CC mode: On, CV mode. Off. Maximum voltage: 30V, maximum sink current: 10mA
12. Enable/Disable
---
Open: Off, Short: On; Dry Contact. Max Voltage @ Enable/Disable In = 6V.
13. Local/Remote mode Control
---
By electrical signal or dry contact (Open/Short), 0~0.6V or short-Remote, 2~15V or open-Local
14. Local/Remote mode Indicator
---
Open collector. Local: open, Remote: ON. Maximum: 30V, maximum sink current 10mA.
2.6.
PROGRAMMING AND READBACK (RS232/485, Optional IEEE Interface)
1. V
out
programming accuracy
---
0.05% of actual output v0.05% of the rated output voltage
2. I
out
programming accuracy (*13)
---
0.1% of actual output c0.2% of rated output current
3. V
out
programming resolution
---
0.012% of full scale.
4. I
out
programming resolution
---
0.012% of full scale.
5. V
out
readback accuracy
---
0.1% of actual output v0.1% of rated output voltage
6. I
out
readback accuracy (*13)
---
0.1% of actual output v0.3% of rated output current
7. V
out
readback resolution
---
0.012% of full scale
8. I
out
readback resolution
0.012% of full scale