53
83503001 Rev G
Table 4-4: J1 Connector Terminals and Functions
J1
contact
Signal name
Function
Reference
J1-1
ENA_IN
Enable/Disable the power supply output by dry-contact (short/open)
with ENA_OUT.
Sec. 5.8
J1-2
J1-3
IF_COM
Isolated Interface Common. Return for the SO control, PS_OK signal
and for the RS232/485 and IEEE interfaces.
Sec. 5.7, 5.10
J1-4
7
N/C
No Connection
J1-8
LOCAL/
REMOTE
Input for selecting between Local or Remote analog programming of
Output Voltage and Output Current.
Sec. 6.2
J1-9
VPGM
Input for remote analog voltage/resistance programming of the
Output Voltage.
Sec. 6.1~6.4
J1-10
IPGM
Input for remote analog voltage/resistance programming of the
Output Current.
Sec. 6.1~6.4
J1-11
VMON
Output for monitoring the power supply Output Voltage.
Sec. 6.6
J1-12
COM
Control Common. Return for VMON, IMON, CV/CC, LOC/REM.
Referenced internally to the negative sense potential.
J1-13
CV/CC
Output for Constant-Voltage/Constant-Current mode
indication.
Sec. 5.9
J1-14
ENA_OUT
Enable/Disable the power supply output by dry-contact (short/open)
with ENA_IN.
Sec. 5.8
J1-15
SO
Input for Shut-Off control of the power supply output.
Sec. 5.7
J1-16
PS_OK
Output for indication of the power supply status.
Sec. 5.10
J1-17
20
N/C
No Connection.
J1-21
LOC/REM
SIGNAL
Output for indicating if the unit is in Local or Remote analog
programming mode.
Sec. 6.3
J1-22
VPGM_RTN
Return for VPGM input. Connected internally to J1-12 terminal.
Sec. 6.1~6.5
J1-23
IPGM_RTN
Return for IPGM input. Referenced internally to the negative output
potential.
Sec. 6.1~6.5
J1-24
IMON
Output for monitoring the power supply Output Current.
Sec. 6.6
J1-25
P
Output for current balance in parallel operation. Connected internally
to J1-24 terminal.
Sec. 5.15