89
83503001 Rev G
8.3.
Isolated Programming & Monitoring Connector
Refer to Table 8-1 for detailed description of the rear panel Isolated Programming &
Monitoring connector. To provide the lowest noise performance, it is recommended to use
shielded-twisted pair wiring.
Refer to Fig.8-1 for description of the Isolated Analog Programming & Monitoring
connector.
Isolated programming plug P/N: MC1.5/8-ST-3.81, Phoenix.
Table 8-1: Detailed Description of Isolated Programming & Monitoring connector
Terminal
Signal name
Function
Range 0-5/0-10V
IS510 option
Range 4-20mA
IS420 option
1
SHLD
Shield, connected internally to chassis of
the power supply.
Chassis ground
2
+VPROG_ISO
Output Voltage programming input
0-5V/0-10V
4-20mA
3
+IPROG_ISO
Output Current programming input
0-5V/0-10V
4-20mA
4
GND
Ground for programming signals.
Ground
Ground
5
GND
Ground for programming signals.
Ground
Ground
6
+VMON_ISO
Output voltage monitoring output
0-5V/0-10V
4-20mA
7
+IMON_ISO
Output current monitoring output
0-5V/0-10V
4-20mA
8
SHLD
Shield, connected internally to chassis of
the supply.
Chassis ground
CAUTION
When the Isolated Analog Option is installed, do not apply any signals to the
non-isolated VPGM and IPGM (J1-9 and J1-10) pins. All other J1 features may
be used normally. Refer to Section 4.5 for a description of J1 features.