-18-
TDK-Lambda
HWS1000 Series
INSTRUCTION MANUAL
5-15. Output peak Current
For model with output peak current, please meet the following condition.
Reduce peak current value according to output derating as section 6-1.
The output is shut down by protection circuit when rated current and continuous peak output time (τ) exceeds rated
value during usage.
When protection circuit is activated, input is temporarily cut off for a few minutes and then power is re-input or
remote ON/OFF control signal should be input for recovery of the output.
Input voltage range
:
AC180V - 265V
Continuous Peak output time.(τ)
:
Within 10 seconds
Peak output current(
Ip
)
:
Within the rated peak output current
Duty
:
up to 35
%
Duty =
x 100
(
%
)
Condition 1
Ip
2
×
< Irms max
Condition 2
(
Ip1
2
×
+ a
2
×
( 1
-
) < Irms max
Ip,Ip1
Irms
τ
T
Model
Irms max
HWS1000-7
94.6A
HWS1000-12
59.1A
HWS1000-15
47.3A
HWS1000-24
34.6A
HWS1000-36
23.0A
HWS1000-48
17.2A
HWS1000-60
13.8A
τ
T
τ
T
τ
T
τ
T
0A
Ip
τ
T
0A
Ip1
τ
T
aA
: Peak output current (A)
: Effective current (A)
: Peak current pulse width (sec)
: cycle (sec)