CAUTION ON USE 

  Product individual notes are shown in the instruction manual.   

If there is any difference with common notes individual notes shall have priority. 

  Before using this product, be sure to read the catalog and instruction manual.   

There is risk of electric shock or damage to the product or fire due to improper use. 

  Input  voltage,  Output  current,  Output  power,  ambient  temperature  and  ambient  humidity  should  be  kept  within  specifications, 

otherwise the product will be damaged, or cause electric shock or fire.   

  If the built-in fuse is blown, do not use the product even after replacing the fuse, as there is risk of abnormality inside. 

Be sure to request repair to our company. 

  For products without built-in protection circuit (element, fuse, etc.), insert fuse at the input to prevent smoke, fire during abnormal 

operation. 
As for products with built-in protection circuit, depending on usage conditions, built-in protection circuit might not work. 
It is recommended to provide separate proper protection circuit. 

  For externally mounted fuse do not use other fuses aside from our specified and recommended fuse. 

  This product was made for general purpose electronic equipment use and is not designed for applications requiring high safety 

(such as extremely high reliability and safety requirements. Even though high reliability and safety are not required, this product 
should not be used directly for applications that have serious risk for life and physical safety. 
Take  sufficient  consideration  in  fail-safe  design  (such  as  providing  protective  circuit  or  protective  device  inside  the  system, 
providing redundant circuit to ensure no instability when single device failure occurs). 

  When used in environments with strong electromagnetic field, there is possibility of product damage due to malfunction. 

  When used in environment with corrosive gas (hydrogen sulfide, sulfur dioxide, etc.) , there is possibility that they might penetrate 

the product and lead to failure. 

  When used in environments where there is conductive foreign matter or dust, there is possibility of product failure or malfunction. 

  Provide countermeasure for prevention of lightning surge voltage as there is risk of damage due to abnormal voltage.   

  Connect  together  the  frame  ground  terminal  of  the  product  and  the  ground  terminal  of  the  equipment  for  safety  and  noise 

reduction. If these ground is not connected together, there is risk of electric shock. 

  Parts with lifetime specifications (built-in fan electrolytic capacitor) are required to be replaced periodically.   

Set the overhaul period depending on the environment of usage and perform maintenance.   
Also, note that there are cases when EOL products cannot be overhauled. 

  Take care not to apply external abnormal voltage to the output. Especially, applying reverse voltage or overvoltage more than the 

rated voltage to the output might cause failure, electric shock or fire. 

  This product is designed under condition Material group IIIb, Pollution Degree (PD): PD2, Over Voltage category (OVC): OVC II 

and Class of equipment: Class I. 
This product is designed to be accessible only to service technicians as part of indoor use device. 

  Power supplies with an output voltage of 48Vdc or less must be earthed in the end use equipment to maintain SELV. 

If the outputs are not earthed, they must be considered hazardous and must not be made user accessible. 

  Power supplies with an output voltage of 60Vdc are considered to be non-SELV. As a result of this, the output must be guarded or 

a deflector fitted during installation to avoid a SERVICE ENGINEER making inadvertent contact with the output terminals, or 
dropping a tool onto them. The output of this product must not be connected to a SELV circuit. 

  The output voltage of this power supply unit is considered to be a hazardous energy level (The voltage is 2V or more and the 

electric  power  is  240VA  or  more),  prevention  from  direct  contact  with  voltage  output  is  highly  necessary.  While  installing  or 
servicing  this  power  supply  unit,  avoid  dropping  tools  by  mistake  or  direct  contact  with  voltage  output.  This  might  cause  an 
electrical  shock.  While  repairing  this  power  supply  unit,  the  AC  input  power  must  be  switch  off  and  the  I/O  terminal  voltage 
should be less than the safety level. 

  This product have a built-in fan for air-cooling. Do not block the air intake and exhaust as this might lead to fire. 

 

Summary of Contents for HWS1000 Series

Page 1: ...changed or dis assembled Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc Please stop using it immediately and shut off the product It might le...

Page 2: ...ity of product failure or malfunction Provide countermeasure for prevention of lightning surge voltage as there is risk of damage due to abnormal voltage Connect together the frame ground terminal of...

Page 3: ...anical stress applied directly to the product Please keep away from direct sunlight For long term storage temperature and humidity the following conditions shall be used as a guideline Temperature ran...

Page 4: ...or use the shielded wire Remote ON OFF control lines shall be twisted or use the shielded wire 2 1 Front Panel Explanation HWS1000 Front Panel Output terminal Output terminal ON Output Power On indic...

Page 5: ...sensing function is unnecessary 5 PC Current balance terminal For output current balancing in parallel operation 6 COM Ground for PC and PV signal 7 PV Output voltage external control terminal For po...

Page 6: ...deteriorate when the sensing terminals are opened In the following cases the output is shut down When CNT and TOG is opened When PV and REF is opened Attached connector when shipping Connecting circu...

Page 7: ...ached to the product Connector JST S12B PHDSS Remove standard attached connector and use the harness made by the customer Housing JST PHDR 12VS Contact JST SPHD 001T P0 5 1 2 3 4 7 8 should be shorted...

Page 8: ...t 85 265VAC FG Output CNT TOG Remote ON OFF Control S S COM PV Output Current Balance PC PF Standby supply Latch Circuit OVP Circuit UVP Circuit Low output Voltage Detection Photo coupler Delay Circui...

Page 9: ...OFF REMOTE OFF REMOTE OFF REMOTE ON REMOTE ON REMOTE ON REMOTE ON FAN STOP FAN ALM ACTION OCP SHUT DOWN 5sec TYP 5sec TYP OCP Point 105 or more 3 OCP Shut down 1 Level 2 4V H 12V or Open 0V L 0 8V or...

Page 10: ...wn type is provided OCP function operates when the output current exceeds 105 of maximum DC output current specification and the over current or short circuit condition continues 5 second or more the...

Page 11: ...t is connected The output is turned to ON when TOG and CNT terminals are shorted and output is turned to OFF when these terminals are opened When the function is not used connect TOG and CNT terminals...

Page 12: ...pe is too long 5 10 Series Operation For series operation either method A or B is possible There might be a step in the rise waveform during series operation Note1 Please connect a diode for by pass w...

Page 13: ...r supply to be same value within 1 or 100mV whichever is smaller 2 Use same length and type of wires for all load lines 3 Maximum value of output current in parallel is up to 80 of all paralleled mode...

Page 14: ...Output CNT PF 100mA The applied voltage must be gradually increased from zero to testing value and then gradually decreased for shut down When timer is used the power supply may be damaged by high im...

Page 15: ...re will be no output Please consider the following characteristics below when operating the unit Connection Method Output Voltage Linearity Output FG chassis 500VAC 1min 300mA Output CNT PF 100VAC 1mi...

Page 16: ...use the output voltage within 20 120 of rated output voltage value 3V model 30 120 48V 60V model 20 110 Wires for control lines must be twisted wire or shield wire In addition maximum variable voltage...

Page 17: ...own low output detection function PF triggers the PF signal and set it to H and also output LED is switch off Under voltage lock out protection mode switch off input for a few minutes and then switch...

Page 18: ...cut off for a few minutes and then power is re input or remote ON OFF control signal should be input for recovery of the output Input voltage range AC180V 265V Continuous Peak output time Within 10 se...

Page 19: ...ase note that ventilation will be worsened in a dusty environment 4 Built in fan is limited life part which require periodic replacement Replacement will be charge 5 The ambient temperature of this po...

Page 20: ...or safety purposes connect protective earthing terminal to the mounting set ground terminal 6 Recommended torque for the terminal piece 7 Recommended wiring Recommended circuit protector AC250V20A Rec...

Page 21: ...minal connection is properly tighten by a regulated tightening torque 4 Check if the wire material is not too thin 5 Check if the output voltage control V ADJ is properly adjusted OVP might be trigger...

Page 22: ...iance with the Low Voltage Directive EMC Directive and RoHS Directive UKCA MARKING UKCA Marking when applied to a product or packing material for a product covered by this handbook indicates complianc...

Reviews: